Suppr超能文献

[A case of the ascending aorta and aortic arch replacement with thrombo-occlusion of distal arch and descending aorta surround the modified elephant trunk graft].

作者信息

Rikitake K, Minato N, Murayama J, Ohnishi H

机构信息

Department of Thoracic and Cardiovascular Surgery, Fukuoka Tokushukai Hospital, Japan.

出版信息

Jpn J Thorac Cardiovasc Surg. 1998 Oct;46(10):1065-8. doi: 10.1007/BF03217876.

Abstract

We report a 65-year-old female who had a extensive thoracic aneurysm from ascending aorta to descending thoracic aorta. The patient underwent a graft replacement of ascending aorta and aortic arch using modified elephant trunk method. The surgery was carried out through median sternotomy with profound hypothermia and selective cerebral perfusion. Postoperatively, the patient was recovered without any complications except bronchial asthma. Postoperative chest computed tomography showed that the surrounding space of the elephant trunk vascular graft inserted into distal arch and descending aneurysm was mostly occupied with thrombus. Therefore, we considered that the second operation on the descending aorta is not necessary at this point and careful attention to the size and shape of the descending aneurysm should be paid.