Pump H, Moehlenkamp S, Sehnert C, Schimpf S S, Erbel R, Seibel R M, Groenemeyer D H
Institute of Diagnostic and Interventional Radiology, Ruhr, Germany.
Acad Radiol. 1998 Dec;5(12):858-62. doi: 10.1016/s1076-6332(98)80247-x.
Coronary artery stents reduce the rate of restenosis in patients who have undergone balloon angioplasty; therefore, the implantation of coronary stents represents an important method in the treatment of coronary stenoses. The authors' purpose was to investigate the usefulness of electron-beam computed tomography (CT) as a noninvasive means of assessing the patency of coronary artery stents in patients who had undergone balloon angioplasty and stent placement.
Electron-beam CT was used to assess stent patency in 177 patients with 285 stents. Contrast material-enhanced multisection flow studies were performed, and the images were evaluated by three investigators and compared with the findings of coronary angiography.
Cine loop evaluations and time-attenuation curve analysis led to the correct diagnosis in 167 (94.3%) patients, as confirmed with coronary angiography. Stenoses had occurred in 18 of the 194 vessels with stents, and 14 of these were detected with electron-beam CT.
Electron-beam CT appears to be a valuable imaging modality in the noninvasive assessment of stent patency in coronary arteries.
冠状动脉支架可降低接受球囊血管成形术患者的再狭窄率;因此,冠状动脉支架植入是治疗冠状动脉狭窄的一种重要方法。作者的目的是研究电子束计算机断层扫描(CT)作为一种非侵入性手段,用于评估接受球囊血管成形术和支架置入术患者冠状动脉支架通畅情况的实用性。
使用电子束CT评估177例患者的285个支架的通畅情况。进行了对比剂增强多层面血流研究,图像由三名研究人员进行评估,并与冠状动脉造影结果进行比较。
电影环评估和时间-衰减曲线分析对167例(94.3%)患者做出了正确诊断,冠状动脉造影证实了这一点。在194个有支架的血管中,有18个出现了狭窄,其中14个通过电子束CT检测到。
电子束CT似乎是冠状动脉支架通畅情况非侵入性评估中有价值的成像方式。