Suppr超能文献

Isotopic ratio analysis in residential lead-based paint and associated surficial dust.

作者信息

Jaeger R J, Weiss A L, Manton W I

机构信息

Environmental Medicine, Inc., Westwood, New Jersey 07675, USA.

出版信息

J Toxicol Clin Toxicol. 1998;36(7):691-703. doi: 10.3109/15563659809162617.

Abstract

OBJECTIVES

This investigation assessed the contribution of lead in lead-based paint (7 samples) to lead-laden dust (8 samples) in a single suburban vacant residence using isotopic ratio analysis.

METHODS

Interior/exterior lead-based paint surface concentration was measured by X-ray fluorescence while dust and scrapings were analyzed chemically for total lead content and by mass spectrometry for the associated isotopic ratios.

RESULTS

Four out of 5 comparisons of paint (7 samples) and dust (8 samples) for a given location did not match isotopically. In the one location where the isotopic ratio of the paint and dust samples matched closely, some portions of the paint were not intact. One explanation for the isotopic ratio match is that the dust sample may have actually been contaminated with paint flecks. This explanation appears likely since the isotopic ratio for the lead in the dust and paint sample were not in the modern average range of US environmental lead, strongly indicating a local point source of the lead in this dust sample, namely the paint at this location. Lead dust samples whose isotopic ratio lies in the modern average range for US environmental lead cannot be correlated to the paint which is beneath them, since the isotopic ratio of lead in the dust may actually be a composite of many sources of lead over time, as suggested by an isotopic ratio in the modern average range.

CONCLUSIONS

From the samples from this one house, the data dispute the contention that intact lead-based paint chalks and creates lead-contaminated dust on its surface. While leaded household dust may contribute to children's lead exposure, intact paint need not contribute to surficial lead-laden dust. Isotopic ratio measurements can be useful for point-source determination by virtue of sample match and by placement of the ratio on the spectrum of isotopic ratio values for lead. Point-source assessment based on isotopic ratio was either strengthened or weakened by placement outside or within the average range for US environmental lead, respectively.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验