Malina M, Lindblad B, Ivancev K, Lindh M, Malina J, Brunkwall J
Department of Vascular Surgery, Malmö University Hospital, Lund University, Sweden.
J Endovasc Surg. 1998 Nov;5(4):310-7. doi: 10.1177/152660289800500404.
To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta.
Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force.
The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p < 0.001. Both hooks and barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects.
Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.
研究带有倒钩和刺的支架是否能改善腹主动脉内覆膜支架移植物的固定效果。
将直径为16至24毫米的涤纶移植物植入尸体主动脉内。如同血管内腹主动脉瘤修复术那样,用支架固定移植物。使用改良的自膨式Z形支架进行了137次覆膜支架移植物植入操作,其中(A)无倒钩和刺(n = 75),(B)有4个5毫米长的倒钩和刺(n = 39),(C)有8个10毫米长的加强倒钩和刺(n = 19),或(D)仅有倒钩(n = 4)。施加逐渐增加的纵向牵引力,以确定取出覆膜支架移植物所需的移位力。测量支架的径向力,并将其与移位力相关联。
取出由支架A固定的移植物所需的中位(四分位间距)移位力为2.5牛(2.0至3.4),支架B为7.8牛(7.4至10.8),支架C为22.5牛(17.1至27.9),p < 0.001。倒钩和刺均增加了固定强度。在牵引过程中,较脆弱的刺会变形或导致内膜撕裂。较强的刺则能与整个主动脉壁接合。支架的径向力对固定效果无影响,而主动脉钙化和移植物尺寸过大有轻微影响。
支架倒钩和刺使覆膜支架移植物的固定效果提高了十倍,而支架的径向力并无影响。这些数据可能对未来防止动脉瘤切除术后覆膜支架移植物移位的血管内移植物开发具有重要意义。