Stephenson J L, McLuckey S A
Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Tennessee 37831-6365, USA.
J Am Soc Mass Spectrom. 1998 Jun;9(6):585-96. doi: 10.1016/S1044-0305(98)00025-7.
Oligopeptide mixtures have been subjected to electrospray ionization, accumulated within a quadrupole ion trap, and subjected to ion/ion proton transfer reactions with anions derived from perfluoro-1,3-dimethylcyclohexane. Various mixtures were studied with approximate molecular weight ranges of 0.5-8.5, 12-30, 45-100, and 0.5-100 kDa. Mixtures of known composition were studied to evaluate the mixture complexity amenable to electrospray combined with ion/ion reactions to reduce spectral complexity associated with multiple charging. Mixture analysis with at least 40 components of low and medium molecular weight and roughly comparable solution concentrations appears to be straightforward. No matrix effects upon ionization were implicated in the data for the low and medium molecular weight mixtures but bovine albumin appeared to inhibit signals from bovine transferrin and chicken conalbumin in the high molecular weight mix. Furthermore, the presence of abundant low mass-to-charge ions appeared to inhibit signals from high molecular weight proteins (> 40 kDa) in the 0.5-100 kDa mix. Such an observation is consistent with dynamic range limitations that can arise from discrimination based on ion space charge effects, although an ionization matrix effect could not be precluded from the data reported here. The results reported here indicate that the limitation to mixture complexity amenable to electrospray mass spectrometry imposed by spectral congestion associated with multiple charging can be significantly reduced via ion/ion reactions. The use of ion/ion reactions can therefore facilitate the study of other factors that can impose limitations to mixture analysis, such as matrix effects upon ionization and differences in ion transmission, accumulation, storage, and detection efficiencies.
寡肽混合物已进行电喷雾电离,在四极离子阱中积累,并与全氟 - 1,3 - 二甲基环己烷衍生的阴离子进行离子/离子质子转移反应。研究了各种混合物,其近似分子量范围为0.5 - 8.5、12 - 30、45 - 100和0.5 - 100 kDa。研究了已知组成的混合物,以评估适合电喷雾结合离子/离子反应的混合物复杂性,以降低与多重电荷相关的光谱复杂性。对至少含有40种低分子量和中等分子量且溶液浓度大致相当的组分的混合物进行分析似乎很简单。对于低分子量和中等分子量混合物的数据,未发现电离时存在基质效应,但在高分子量混合物中,牛血清白蛋白似乎会抑制牛转铁蛋白和鸡伴清蛋白的信号。此外,在0.5 - 100 kDa混合物中,大量低质荷比离子的存在似乎会抑制高分子量蛋白质(> 40 kDa)的信号。尽管根据此处报告的数据不能排除电离基质效应,但这种观察结果与基于离子空间电荷效应的歧视可能产生的动态范围限制是一致的。此处报告的结果表明,通过离子/离子反应可以显著降低与多重电荷相关的光谱拥塞对适合电喷雾质谱分析的混合物复杂性的限制。因此,离子/离子反应的使用可以促进对其他可能限制混合物分析的因素的研究,例如电离时的基质效应以及离子传输、积累、存储和检测效率的差异。