Danek A, Poczatek J
Arzneimittelforschung. 1976;26(3):321-4.
A simple electronic circuit is constructed for simulation of the theoretical curves associated with single and multiple dosing kinetics. The output is an analog device which generates plasma concentration curves versus time, consistent with the assumption in a one-compartment open model with rapid intravenous injection or first-order absorption. Potentiometer settings offer variations in dosing schedules, distribution volumes as well as in absorption and elimination rate constants. All details are made from standard electronic components. The device can be used in teaching of the elements of pharmacokinetics.
构建了一个简单的电子电路,用于模拟与单剂量和多剂量动力学相关的理论曲线。输出是一个模拟装置,它生成血浆浓度随时间变化的曲线,这与快速静脉注射或一级吸收的一室开放模型中的假设一致。电位器设置可改变给药方案、分布容积以及吸收和消除速率常数。所有细节均由标准电子元件制成。该装置可用于药代动力学原理的教学。