Suppr超能文献

初次混合式全髋关节置换术,髋臼组件非骨水泥植入,股骨组件预涂骨水泥。平均十年随访研究。

Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.

作者信息

Clohisy J C, Harris W H

机构信息

Department of Orthopaedic Surgery, Washington University Medical Center, St. Louis, Missouri 63110, USA.

出版信息

J Bone Joint Surg Am. 1999 Feb;81(2):247-55. doi: 10.2106/00004623-199902000-00012.

Abstract

One hundred and twenty-one primary hybrid total hip replacements were performed in 107 patients. A titanium, porous-coated, hemispherical acetabular component was fixed with screws, and a collared, chromium-cobalt femoral stem, with a roughened surface and a thin layer of methylmethacrylate on the proximal third, was inserted with contemporary cementing techniques (that is, use of a femoral medullary plug, a cement gun, and centrifugation and pressurization of the cement). Fifteen patients (fifteen hips) died before a minimum duration of follow-up of seven years, four patients (four hips) were too ill for a detailed follow-up examination at the time of the study, and two patients (two hips) refused to be evaluated at the time of the latest follow-up. None of these twenty-one hips had had a revision or a reoperation at the time of the latest follow-up. Eighty-six patients (100 hips) were available for clinical follow-up at an average of 120 months (range, eighty-four to 153 months) and for radiographic follow-up at an average of 118 months (range, eighty-four to 153 months). The average age of the patients at the time of the index arthroplasty was sixty-five years (range, forty-five to eighty-seven years). Three acetabular components were revised because of dissociation of the liner in association with a fracture of a locking tine. One well fixed acetabular component was revised because of pelvic osteolysis, and the femoral stem in the same patient was revised because of aseptic loosening. None of the ninety-six remaining acetabular components migrated, was classified as radiographically loose, or was revised because of aseptic loosening. Osteolytic lesions were identified adjacent to five acetabular components, and one of them was treated with bone-grafting around the well fixed acetabular shell. Two hips had a continuous radiolucent line at the interface between the acetabular implant and the bone. Three femoral stems had evidence of radiographic debonding (a radiolucent line that was one millimeter wide or less between the cement and the prosthesis), and they were classified as radiographically loose despite excellent clinical results. Seven hips had osteolytic areas located in the proximal aspect of the most proximal zones of Gruen et al., and five had small osteolytic regions in more distal areas. The Harris hip score for the eighty-two patients (ninety-six hips) who did not have a revision improved from 48 points (range, 22 to 70 points) preoperatively to 92 points (range, 53 to 100 points) at the most recent follow-up examination. Eighty-one patients had no, slight, or mild pain in the hip, and they were satisfied with the clinical result. In the present study, the hybrid total hip replacement with use of the Harris-Galante acetabular component and the Precoat femoral stem continued to provide an excellent result for most patients at an average of approximately ten years after the operation.

摘要

对107例患者实施了121例初次混合式全髋关节置换术。用螺钉固定一个钛制、多孔涂层的半球形髋臼组件,采用现代骨水泥固定技术(即使用股骨髓腔塞、骨水泥枪以及对骨水泥进行离心和加压)植入一个带颈的铬钴合金股骨干,其表面粗糙,近端三分之一处有一层薄薄的甲基丙烯酸甲酯。15例患者(15髋)在至少7年的随访期前死亡,4例患者(4髋)在研究时病情过重无法进行详细的随访检查,2例患者(2髋)在最近一次随访时拒绝接受评估。在最近一次随访时,这21髋均未进行翻修或再次手术。86例患者(100髋)可进行平均120个月(范围84至153个月)的临床随访以及平均118个月(范围84至153个月)的影像学随访。初次关节置换时患者的平均年龄为65岁(范围45至87岁)。3个髋臼组件因衬垫分离伴锁定齿骨折而进行翻修。1个固定良好的髋臼组件因骨盆骨溶解而翻修,同一患者的股骨干因无菌性松动而翻修。其余96个髋臼组件均未发生移位,影像学上未分类为松动,也未因无菌性松动而翻修。在5个髋臼组件旁发现溶骨性病变,其中1个在固定良好的髋臼壳周围进行了植骨治疗。2髋在髋臼植入物与骨之间的界面处有连续的透亮线。3个股骨干有影像学上脱粘的证据(骨水泥与假体之间有一条1毫米宽或更窄的透亮线),尽管临床结果良好,但它们在影像学上被分类为松动。7髋在Gruen等人定义的最近端区域的近端有溶骨区,5髋在更远端区域有小的溶骨区。82例未进行翻修的患者(96髋)的Harris髋关节评分从术前的48分(范围22至70分)提高到最近一次随访检查时的92分(范围53至100分)。81例患者髋部无疼痛、轻微疼痛或轻度疼痛,他们对临床结果满意。在本研究中,使用Harris-Galante髋臼组件和Precoat股骨干的混合式全髋关节置换术在术后平均约10年时,对大多数患者仍能持续提供优异的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验