Suppr超能文献

剖宫产时0.5% 硬膜外左旋布比卡因与布比卡因的临床效果及母胎血浆浓度比较

Clinical effects and maternal and fetal plasma concentrations of 0.5% epidural levobupivacaine versus bupivacaine for cesarean delivery.

作者信息

Bader A M, Tsen L C, Camann W R, Nephew E, Datta S

机构信息

Department of Anesthesia, Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.

出版信息

Anesthesiology. 1999 Jun;90(6):1596-601. doi: 10.1097/00000542-199906000-00015.

Abstract

BACKGROUND

Bupivacaine exists as a mixture of two enantiomers, levobupivacaine and dexbupivacaine. Data suggest that levobupivacaine has equal local anesthetic potency, with reduced potential for central nervous system and cardiovascular toxicity. The present study compares the efficacy of 0.5% levobupivacaine with 0.5% bupivacaine for epidural anesthesia in parturients undergoing elective cesarean delivery.

METHODS

Sixty healthy obstetric patients undergoing elective cesarean delivery with epidural anesthesia completed the study. Patients were randomized to receive 30 ml of either 0.5% levobupivacaine or 0.5% bupivacaine in a double-blind fashion. The efficacy endpoint measures included onset, offset, and quality of anesthesia. Neonatal blood gas analyses, Apgar score determinations, and neurobehavioral examinations were performed. Venous samples for pharmacokinetic studies and serial electrocardiograms were obtained in 10 patients in each group.

RESULTS

Levels of sensory block, motor block, muscle relaxation, and overall quality of anesthesia did not differ between groups. The frequency of hypotension was 84.4% in the levobupivacaine group and 100% for the bupivacaine group (P < or = 0.053). No significant difference in observed maximum concentration of drug after dosing or area under the plasma drug concentration versus time curve were seen. The maximum concentrations were 1.017 and 1.053 microg/ml, and the areas were 4.082 and 3.765 h(microg/ml) for the levobupivacaine and bupivacaine groups, respectively. Umbilical vein-to-maternal vein ratios were 0.303 for the levobupivacaine group and 0.254 for the bupivacaine group.

CONCLUSIONS

The use of epidural 0.5% levobupivacaine for cesarean delivery results in equally efficacious anesthesia compared with 0.5% bupivacaine. Pharmacokinetic parameters were similar in the two groups.

摘要

背景

布比卡因以左旋布比卡因和右旋布比卡因两种对映体的混合物形式存在。数据表明,左旋布比卡因具有同等的局部麻醉效力,同时中枢神经系统和心血管毒性的可能性降低。本研究比较了0.5%左旋布比卡因与0.5%布比卡因用于择期剖宫产产妇硬膜外麻醉的效果。

方法

60例接受硬膜外麻醉的择期剖宫产健康产科患者完成了本研究。患者以双盲方式随机接受30毫升0.5%左旋布比卡因或0.5%布比卡因。疗效终点指标包括起效时间、消退时间和麻醉质量。进行了新生儿血气分析、阿氏评分测定和神经行为检查。每组10例患者采集用于药代动力学研究的静脉血样和连续心电图。

结果

两组之间的感觉阻滞水平、运动阻滞、肌肉松弛和总体麻醉质量无差异。左旋布比卡因组低血压发生率为84.4%,布比卡因组为100%(P≤0.053)。给药后观察到的药物最大浓度或血浆药物浓度-时间曲线下面积无显著差异。左旋布比卡因组和布比卡因组的最大浓度分别为1.017和1.053微克/毫升,曲线下面积分别为4.082和3.765小时(微克/毫升)。左旋布比卡因组脐静脉与母血静脉比值为0.303,布比卡因组为0.254。

结论

与0.5%布比卡因相比,剖宫产时使用硬膜外0.5%左旋布比卡因产生的麻醉效果相同。两组的药代动力学参数相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验