Suppr超能文献

腹部屏气对比增强三维磁共振血管造影:时间分辨成像与单相成像对比

Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: time-resolved imaging versus single-phase imaging.

作者信息

Van Hoe L, De Jaegere T, Bosmans H, Stockx L, Vanbeckevoort D, Oyen R, Fagard R, Marchal G

机构信息

Department of Radiology, University Hospitals, Katholieke Universiteit Leuven, Belgium.

出版信息

Radiology. 2000 Jan;214(1):149-56. doi: 10.1148/radiology.214.1.r00ja12149.

Abstract

PURPOSE

To evaluate a technique for time-resolved breath-hold contrast material-enhanced three-dimensional magnetic resonance (MR) angiography of the abdomen.

MATERIALS AND METHODS

In a prospective study, 43 patients underwent time-resolved MR angiography (acquisition time per data set, 7 seconds). The patients also underwent single-phase high-spatial-resolution MR angiography (acquisition time, 27 seconds) (n = 6), conventional angiography (n = 7), or both (n = 30). No bolus timing study was performed for time-resolved MR angiography. Image quality (presence of artifacts, ability to prevent venous overlap on arterial phase images, contrast enhancement) and demonstration of anatomic variants (renal arterial and venous variants, vena caval anomaly, visceral arterial variants) and vascular diseases were assessed.

RESULTS

Time-resolved MR angiographic images were characterized by fewer and less severe artifacts, less overlap of enhancing veins, and better contrast enhancement than were single-phase MR angiographic images (P < .05). The mean sensitivity and specificity were 90% (nine of 10) and 100% (1 73 of 1 73), respectively, for detection of arterial anatomic variants and 93% (28 of 30) and 100% (324 of 325), respectively, for detection of disease. The technique also proved to be reliable for demonstration of venous disease.

CONCLUSION

In comparison with current non-time-resolved MR angiographic techniques, time-resolved MR angiography is more robust and easier to perform and allows simultaneous evaluation of arterial and venous disease.

摘要

目的

评估一种用于腹部时间分辨屏气对比剂增强三维磁共振(MR)血管造影的技术。

材料与方法

在一项前瞻性研究中,43例患者接受了时间分辨MR血管造影(每组数据集采集时间为7秒)。这些患者还接受了单相高空间分辨率MR血管造影(采集时间为27秒)(n = 6)、传统血管造影(n = 7)或两者都接受了(n = 30)。时间分辨MR血管造影未进行团注时间研究。评估图像质量(伪影的存在、动脉期图像上防止静脉重叠的能力、对比增强)以及解剖变异(肾动脉和静脉变异、腔静脉异常、内脏动脉变异)和血管疾病的显示情况。

结果

与单相MR血管造影图像相比,时间分辨MR血管造影图像的特点是伪影更少、更不严重,增强静脉的重叠更少,对比增强更好(P <.05)。检测动脉解剖变异的平均敏感性和特异性分别为90%(10例中的9例)和100%(173例中的173例),检测疾病的平均敏感性和特异性分别为93%(30例中的28例)和100%(325例中的324例)。该技术在显示静脉疾病方面也被证明是可靠的。

结论

与目前的非时间分辨MR血管造影技术相比,时间分辨MR血管造影更稳健、更易于操作,并且能够同时评估动脉和静脉疾病。