Suppr超能文献

硝酸甘油的快速准确的稳定性指示测定法。

Rapid and accurate stability-indicating assay for nitroglycerin.

作者信息

Baaske D M, Carter J E, Amann A H

出版信息

J Pharm Sci. 1979 Apr;68(4):481-3. doi: 10.1002/jps.2600680423.

Abstract

A rapid high-pressure liquid chromatographic method for determining the nitroglycerin concentration in liquid dosage forms and intravenous admixture solutions is presented. A coefficient of variation of less than 1.8% was achieved over the concentration range most commonly encountered (50-500 microgram/ml). A variable wavelength detector (lambda = 218 nm) and a micro-alkyl phenyl column were employed. The mobile phase was acetonitrile-tetrahydrofuran-water (26:10:64). Total analysis time was 12 min.

摘要

本文介绍了一种用于测定液体制剂和静脉混合溶液中硝酸甘油浓度的快速高压液相色谱法。在最常遇到的浓度范围(50 - 500微克/毫升)内,变异系数小于1.8%。采用可变波长检测器(λ = 218纳米)和微烷基苯基柱。流动相为乙腈 - 四氢呋喃 - 水(26:10:64)。总分析时间为12分钟。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验