Guller B, Yipintsoi T, Orvis A L, Bassingthwaighte J B
Circ Res. 1975 Sep;37(3):359-78. doi: 10.1161/01.res.37.3.359.
Sudden injections of boluses containing both 131I-albumin and 24NaCl were made into the coronary artery inflow of isolated blood-perfused dog hearts. Indicator dilution curves were recorded using gamma emissions from both the intact heart and the coronary sinus outflow, with plasma flows, Fs, ranging from 0.3 to 1.8 ml/g min-1. Three measures of sodium extraction, E, during transcapillary passage were obtained from each site by comparison of the sodium and albumin curves. The most useful estimates of E were "instantaneous extractions" obtained from the later part of the upslope and the peak of the venous dilution curves (coronary sinus) or from the corresponding early phase of washout of the externally monitored curves (intact organ). Extractions were lower at higher flows. Permeability-surface area products, PS, were computed (1) by the formula PS equals -Fsloge(1 - E), (2) by fitting the observed dilution curves with a Krogh capillary-tissue cylinder model, and (3) by the approximating formula PS equals -Fsloge (1 - 1.14E). The two latter approaches provided a correction for back diffusion of tracer from tissue to blood. For sodium, the values of PS averaged 0.88 +/- 0.36 (SD) ml/g min-1, (n equals 52). At high flows, with Fs greater than 1.0 ml/g min-1, the values of PS averaged 1.01 +/- 0.38 ml/g min-1 (N equals 11). Assuming S equals 500 cm2/g and plasma to be 93% water, our findings suggest capillary permeabilities for sodium of about 3.1 times 10(-5) cm/sec.
将含有131I - 白蛋白和24NaCl的大剂量注射液突然注入离体血液灌注犬心脏的冠状动脉流入端。利用来自完整心脏和冠状窦流出端的γ射线发射记录指示剂稀释曲线,血浆流量Fs范围为0.3至1.8 ml/g·min-1。通过比较钠和白蛋白曲线,从每个部位获得了跨毛细血管通过期间钠提取的三种测量值E。对E最有用的估计是从静脉稀释曲线(冠状窦)的上升斜率后期和峰值或从外部监测曲线(完整器官)冲洗的相应早期阶段获得的“瞬时提取”。在较高流量下提取率较低。计算了通透表面积乘积PS:(1)通过公式PS等于 -Fsloge(1 - E);(2)通过用克勒毛细血管 - 组织圆柱体模型拟合观察到的稀释曲线;(3)通过近似公式PS等于 -Fsloge(1 - 1.14E)。后两种方法对示踪剂从组织到血液的反向扩散进行了校正。对于钠,PS值平均为0.88±0.36(标准差)ml/g·min-1(n = 52)。在高流量下,当Fs大于1.0 ml/g·min-1时,PS值平均为1.01±0.38 ml/g·min-1(N = 11)。假设S等于500 cm2/g且血浆93%为水,我们的研究结果表明钠的毛细血管通透性约为3.1×10(-5) cm/sec。