A prospective, volume-controlled comparison of the BacT/Alert FAN (Organon Teknika, USA) and Vital (bioMérieux, France) blood culture systems was performed in a university hospital during a period of 11 months. Twenty to 40 ml of blood drawn from an adult patient was distributed equally between a BacT/Alert FAN and a Vital blood culture set, both consisting of an aerobic and an anaerobic bottle. Bottles were weighed prior to use and after incubation to calculate the blood volume. A compliant pair of aerobic, or anaerobic, bottles of a blood culture was defined as follows: blood volumes were 4-11 ml and the blood volumes in the two bottles differed by < or =20%. From 120 compliant pairs of aerobic bottles, 135 organisms were recovered, of which 78 were isolated in both bottles, 44 in the BacT/Alert FAN bottle only and 13 in the Vital bottle only (P<0.0005). In particular, aerobic BacT/Alert FAN bottles yielded more members of the family Enterobacteriaceae (P<0.01). The BacT/Alert FAN system also performed significantly better when comparing anaerobic bottles, and the yield was greater during septic episodes. Both culture systems were similar regarding detection time, recovery during antimicrobial therapy, and the occurrence of false-positive and false-negative bottles. The overall performance of the BacT/Alert FAN system was better than that of the Vital system.

摘要

在一家大学医院进行了为期11个月的前瞻性、容量控制的BacT/Alert FAN(美国Organon Teknika公司)和Vital(法国生物梅里埃公司)血培养系统比较。从成年患者抽取20至40毫升血液,在BacT/Alert FAN和Vital血培养套装之间平均分配,两者均由一个需氧瓶和一个厌氧瓶组成。使用前和孵育后对瓶子称重以计算血量。一对符合要求的血培养需氧瓶或厌氧瓶定义如下:血量为4至11毫升,两瓶中的血量相差≤20%。从120对符合要求的需氧瓶中,分离出135种微生物,其中78种在两瓶中均分离到,44种仅在BacT/Alert FAN瓶中分离到,13种仅在Vital瓶中分离到(P<0.0005)。特别是,需氧BacT/Alert FAN瓶分离出更多肠杆菌科成员(P<0.01)。比较厌氧瓶时,BacT/Alert FAN系统的表现也明显更好,在脓毒症发作期间产量更高。两种培养系统在检测时间、抗菌治疗期间的回收率以及假阳性和假阴性瓶的发生率方面相似。BacT/Alert FAN系统的总体表现优于Vital系统。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验