Tissue water content and nuclear magnetic resonance in normal and tumor tissues.

作者信息

Kiricuta I C, Simplăceanu V

出版信息

Cancer Res. 1975 May;35(5):1164-7.

PMID:1120306
Abstract

Pulsed proton nuclear magnetic resonance was used to differentiate between normal and malignant tissues. When the tissue water content varied from 80 to 93%, the tumors exhibited spin-lattice relaxation times (T1) from 0.9 to 1.8 sec. We report also the results obtained on 9-day-old embryos and on liver, brain, and heart from 2-day-old rats. A good correlation between the spin-lattice (T1) and spin-spin (T2) relaxation times and the tissue water content was found for all tissues studied. The relaxation times T1 and T2 and water content in Walker 256 carcinoma and its lymph node metastasis were quite similar.

摘要

脉冲质子核磁共振被用于区分正常组织和恶性组织。当组织含水量在80%至93%之间变化时,肿瘤的自旋晶格弛豫时间(T1)为0.9至1.8秒。我们还报告了在9日龄胚胎以及2日龄大鼠的肝脏、大脑和心脏上所获得的结果。在所研究的所有组织中,均发现自旋晶格(T1)和自旋-自旋(T2)弛豫时间与组织含水量之间存在良好的相关性。Walker 256癌及其淋巴结转移灶的弛豫时间T1、T2以及含水量非常相似。