Yang Z, Du S
Department of Ophthalmology, Tongji Hospital, Tongji Medical University, Wuhan 430030.
J Tongji Med Univ. 2000;20(3):257-60. doi: 10.1007/BF02887007.
The patients with glaucoma underwent the examination of retinal thickness analyzer (RTA) to explore the diagnostic value of RTA in glaucoma. The retina of 6 mm x 6 mm size (approximately 20 degrees, centered on the macula) at the posterior pole was scanned by using RTA to obtain the images in 35 eyes of 22 patients with glaucoma. The images were processed by using SAS software package. The retinal thickness in the patients with glaucoma showed diffuse or local thinning. Twenty-seven eyes was definitely diagnosed as having glaucoma. There was a very significant difference in retinal thickness measurements by RTA between normal group and glaucomatous group (P = 0.0012). Except the measurements at the detected point 6 having no difference, the measurements at the detected point 3 showed a significant difference and the remaining 7 detected points presented a very significant difference between the two groups. Of the detected 9 points, the changes at the points 4, 8, and 9 were the most obvious. The discrete analysis was performed on the glaucomatous patients by a discriminant function established through the data at the detected points 4, 8 and 9 and the accurate estimate rate for the diagnosis of glaucoma was up to 80.77%. The measurements of RTA examination was consistent with the results of the vision field test. It was suggested that diffuse or local thinning of retinal thickness exists in the patients with glaucoma. The temporal inferior arcuate fibers and the papillomacular bundle between the macular and optic nerve heads showed a serious damage. The sensitivity of RTA examination was higher than visual field test.
青光眼患者接受了视网膜厚度分析仪(RTA)检查,以探讨RTA在青光眼诊断中的价值。使用RTA对22例青光眼患者的35只眼后极部6mm×6mm大小(约20度,以黄斑为中心)的视网膜进行扫描,获取图像。图像采用SAS软件包进行处理。青光眼患者的视网膜厚度呈现弥漫性或局限性变薄。27只眼被明确诊断为青光眼。正常组与青光眼组经RTA测量的视网膜厚度差异非常显著(P = 0.0012)。除检测点6的测量值无差异外,检测点3的测量值有显著差异,其余7个检测点两组间差异非常显著。在检测的9个点中,点4、8和9的变化最为明显。利用检测点4、8和9的数据建立判别函数,对青光眼患者进行判别分析,青光眼诊断的准确估计率高达80.77%。RTA检查测量结果与视野检查结果一致。提示青光眼患者存在视网膜厚度弥漫性或局限性变薄,颞下弓形纤维以及黄斑与视乳头之间的乳头黄斑束受损严重,RTA检查的敏感度高于视野检查。