To evaluate the imaging characteristics of an amorphous silicon flat-panel detector (FPD) for digital chest radiography.
The 41 x 41-cm digital FPD is constructed on a single monolithic glass substrate with a structured cesium iodide scintillator layer and an amorphous silicon thin-film transistor array for image readout. Basic imaging characteristics of the FPD and associated image processing system were assessed on acquired images, including linearity, repeatability, uniformity of response, modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), contrast sensitivity, and scatter content. Results with the FPD system were compared to those with a storage phosphor computed radiography (CR) system.
Images obtained with the FPD demonstrated excellent uniformity, repeatability, and linearity, as well as MTF and DQE that were superior to those with the storage phosphor CR system. The contrast and scatter content of images acquired with the FPD were equivalent to those acquired with the storage phosphor system.
The FPD provides radiographic images with excellent inherent physical image quality.
评估用于数字胸部X线摄影的非晶硅平板探测器(FPD)的成像特性。
41×41厘米的数字FPD构建在单个整体玻璃基板上,具有结构化碘化铯闪烁体层和用于图像读出的非晶硅薄膜晶体管阵列。在采集的图像上评估FPD及相关图像处理系统的基本成像特性,包括线性、重复性、响应均匀性、调制传递函数(MTF)、噪声功率谱、探测量子效率(DQE)、对比敏感度和散射含量。将FPD系统的结果与存储磷光体计算机X线摄影(CR)系统的结果进行比较。
用FPD获得的图像显示出优异的均匀性、重复性和线性,以及优于存储磷光体CR系统的MTF和DQE。用FPD采集的图像的对比度和散射含量与用存储磷光体系统采集的图像相当。
FPD提供具有优异固有物理图像质量的X线摄影图像。