Lionheart W R, Kaipio J, McLeod C N
Department of Mathematics, UMIST, UK.
Physiol Meas. 2001 Feb;22(1):85-90. doi: 10.1088/0967-3334/22/1/311.
There are a number of constraints which limit the current and voltages which can be applied on a multiple drive electrical imaging system. One obvious constraint is to limit the maximum ohmic power dissipated in the body. Current patterns optimizing distinguishability with respect to this constraint are singular functions of the difference of transconductance matrices with respect to the power norm (the optimal currents of Isaacson). If one constrains the total current (L1 norm) the optimal patterns are pair drives. On the other hand if one constrains the maximum current on each drive electrode (an L(infinity) norm), the optimal patterns have each drive channel set to the maximum source or sink current value. In this paper we consider appropriate safety constraints and discuss how to find the optimal current patterns with those constraints.
存在许多限制因素,这些因素限制了可应用于多驱动电成像系统的电流和电压。一个明显的限制是限制人体中耗散的最大欧姆功率。关于此限制优化可区分性的电流模式是跨导矩阵相对于功率范数(艾萨克森的最优电流)之差的奇异函数。如果限制总电流(L1范数),则最优模式是成对驱动。另一方面,如果限制每个驱动电极上的最大电流(L无穷范数),则最优模式是将每个驱动通道设置为最大源电流或汇电流值。在本文中,我们考虑了适当的安全限制,并讨论了如何在这些限制下找到最优电流模式。