Postural control in the elderly: an analysis of test-retest and interrater reliability of the COP-COM variable.

作者信息

Corriveau H, Hébert R, Prince F, Raîche M

机构信息

School of Rehabilitation Sciences, Physiotherapy, University of Ottawa, Ottawa, Ont, Canada.

出版信息

Arch Phys Med Rehabil. 2001 Jan;82(1):80-5. doi: 10.1053/apmr.2001.18678.

Abstract

OBJECTIVES

To estimate the test-retest and interrater reliability of the center of pressure-center of mass (COP-COM) variable of postural control in the elderly.

DESIGN

The biomechanic variable COP-COM, which represents the distance between the COP and the COM, was determined from 2 AMTI force platforms and 3 OPTOTRAK position sensors. Measurements were taken in quiet position, double leg stance, and eyes open and eyes closed conditions.

SETTING

Laboratory environment.

PARTICIPANTS

Forty-five healthy subjects, 8 patients with diabetes neuropathy, and 7 stroke survivors, all of whom were at least 60 years old.

INTERVENTIONS

Subjects were evaluated on 2 separate occasions within 7 days by the same evaluator to determine test-retest reliability. Interrater reliability was determined the same day.

MAIN OUTCOME MEASURES

The biomechanic variable COP-COM, which represents the distance between the COP and the COM in terms of root mean square. The mean of 4 trials of the COP-COM variable for each condition was used for statistical analysis. Intraclass correlation coefficients (ICCs) were used.

RESULTS

The COP-COM variable has good reliability for both the test-retest and interrater studies, but its reliability varies according to the direction of the COP-COM. For the test-retest and interrater studies, the ICC ranged from.89 to.93 in the anteroposterior direction and from.74 to.79 in the mediolateral direction.

CONCLUSION

The equivalence of the test-retest and interrater coefficients obtained suggests that the measurement error of the COP-COM variable is mainly linked to the biologic variability of this measure over a short period of time. Using the mean of 4 trials stabilizes the COP-COM variable enough to be potentially used to evaluate clinical change.

摘要

目的

评估老年人姿势控制中压力中心-质心(COP-COM)变量的重测信度和评分者间信度。

设计

生物力学变量COP-COM代表COP与COM之间的距离,由2个AMTI测力平台和3个OPTOTRAK位置传感器测定。在安静姿势、双腿站立、睁眼和闭眼条件下进行测量。

设置

实验室环境。

参与者

45名健康受试者、8名糖尿病神经病变患者和7名中风幸存者,均为60岁及以上。

干预措施

同一评估者在7天内对受试者进行2次独立评估,以确定重测信度。评分者间信度在同一天确定。

主要观察指标

生物力学变量COP-COM,以均方根表示COP与COM之间的距离。每种条件下COP-COM变量4次试验的平均值用于统计分析。使用组内相关系数(ICC)。

结果

COP-COM变量在重测和评分者间研究中均具有良好的信度,但其信度根据COP-COM的方向而有所不同。对于重测和评分者间研究,ICC在前后方向上为0.89至0.93,在内外侧方向上为0.74至0.79。

结论

获得的重测和评分者间系数的等效性表明,COP-COM变量的测量误差主要与该测量在短时间内的生物学变异性有关。使用4次试验的平均值可使COP-COM变量足够稳定,有可能用于评估临床变化。