Lee J S, Park W S, Lee S H, Oum B S, Cho B M
Department of Ophthalmology & Medical Research Institute, College of Medicine, Pusan National University, Korea.
Graefes Arch Clin Exp Ophthalmol. 2001 Jan;239(1):1-4. doi: 10.1007/s004170000223.
To analyze the effect on the morphologic characteristics of the corneal endothelium of the duration of soft contact lens wearing periods.
Ninety soft contact lens wearers were divided into three groups: short-term users, for less than 5 years (n=60 eyes); intermediate-term users, from 6 years to 10 years (n=60); longterm users, for more than 10 years (n=60). Thirty non-contact lens wearers (60 eyes) were included as controls. All eyes were examined with a specular microscope. Analysis of covariance was used to detect any differences among the controls and the various soft contact lens subgroups.
There was a significant correlation between duration of soft contact lens use and morphologic changes of corneal endothelium. All soft contact lens subgroups had a significantly greater coefficient of variation in cell size than non-contact lens users . The proportion of hexagonal cells and the mean corneal endothelial cell density in those using soft contact lenses for more than 6 years were significantly lower than in the control group . Soft contact lens wear was significantly correlated with decreasing corneal endothelial cell densities with time.
The coefficient of variation in cell size may be a sensitive indicator of early morphologic changes of the corneal endothelium. As the decrease in cell density among the contact lens subgroups was significantly associated with the duration of soft contact lens wearing periods, it will be useful to investigate endothelial cell density for evaluation of corneal endothelial function concerned with contact lens wearing.
分析软性接触镜佩戴时间对角膜内皮细胞形态学特征的影响。
90名软性接触镜佩戴者被分为三组:短期使用者,佩戴时间少于5年(60只眼);中期使用者,佩戴时间6至10年(60只眼);长期使用者,佩戴时间超过10年(60只眼)。纳入30名非接触镜佩戴者(60只眼)作为对照组。所有眼睛均用角膜内皮显微镜检查。采用协方差分析检测对照组与各软性接触镜亚组之间的差异。
软性接触镜使用时间与角膜内皮细胞形态学变化之间存在显著相关性。所有软性接触镜亚组的细胞大小变异系数均显著高于非接触镜使用者。使用软性接触镜超过6年者的六角形细胞比例和平均角膜内皮细胞密度显著低于对照组。软性接触镜佩戴与角膜内皮细胞密度随时间降低显著相关。
细胞大小变异系数可能是角膜内皮细胞早期形态学变化的敏感指标。由于接触镜亚组中细胞密度的降低与软性接触镜佩戴时间显著相关,因此研究内皮细胞密度对于评估与接触镜佩戴相关的角膜内皮功能将是有用的。