Suppr超能文献

二维梯度回波、快速自旋回波和二维快速梯度自旋回波序列在颈椎脊髓解剖结构磁共振成像中的比较。

Comparison of two-dimensional gradient echo, turbo spin echo and two-dimensional turbo gradient spin echo sequences in MRI of the cervical spinal cord anatomy.

作者信息

Held P, Seitz J, Fründ R, Nitz W, Lenhart M, Geissler A

机构信息

Department of Diagnostic Radiology, University of Regensburg, University Hospital, 93042, Regensburg, Germany.

出版信息

Eur J Radiol. 2001 Apr;38(1):64-71. doi: 10.1016/s0720-048x(00)00253-9.

Abstract

The aim of this study was to assess the detectability and distinguishability of the cervical spinal cord, the anterior and posterior spinal roots and of the internal anatomy of the cord (distinction of grey and white matter). For this purpose 20 healthy volunteers were examined using a 1.5 T MR unit with 20 mT/m gradient strength and a dedicated circular polarized neck array coil. Three T2* weighted (w). 2D gradient echo sequences, two T2 w. 2D turbo spin echo (TSE) sequences and one T2 w. 2D turbo gradient spin echo (TGSE) sequence were compared. The multiecho 2D fast low angle shot (FLASH) sequence with magnetization transfer saturation pulse (me FLASH+MTS) yielded the best results for liquor/compact bone, liquor/spinal cord and grey/white matter contrast, as found with regions of interest (ROI) analysis. The single echo 2D FLASH sequence was significantly poorer than the two me FLASH+/-MTS sequences. Two-dimensional TGSE as well as 2D TSE with a 256 matrix and with a 512 matrix yielded the poorest results. In the visual analysis the contrast between liquor and compact bone, liquor and cord as well as liquor and roots was best with me FLASH+MTS, whereas grey/white matter distinction was best using me FLASH-MTS. In conclusion, we would therefore recommend the inclusion of an axial T2* w. multiecho 2D spoiled gradient echo sequence with magnetization transfer saturation pulse and gradient motion rephasing in a MR imaging protocol of the cervical spine.

摘要

本研究的目的是评估颈脊髓、脊髓前后根以及脊髓内部解剖结构(灰质和白质的区分)的可检测性和可区分性。为此,使用一台1.5T磁共振成像设备,其梯度强度为20mT/m,配备专用的圆极化颈部阵列线圈,对20名健康志愿者进行了检查。比较了三个T2加权(w)二维梯度回波序列、两个T2加权二维快速自旋回波(TSE)序列和一个T2加权二维快速梯度自旋回波(TGSE)序列。通过感兴趣区(ROI)分析发现,带有磁化传递饱和脉冲的多回波二维快速低角度激发(FLASH)序列(me FLASH+MTS)在脑脊液/致密骨、脑脊液/脊髓以及灰质/白质对比度方面产生了最佳结果。单回波二维FLASH序列明显比两个me FLASH+/-MTS序列差。二维TGSE以及矩阵为256和512的二维TSE产生的结果最差。在视觉分析中,me FLASH+MTS在脑脊液与致密骨、脑脊液与脊髓以及脑脊液与神经根之间的对比度方面表现最佳,而me FLASH-MTS在灰质/白质区分方面表现最佳。总之,因此我们建议在颈椎磁共振成像方案中纳入一个带有磁化传递饱和脉冲和梯度运动重聚的轴向T2加权多回波二维扰相梯度回波序列。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验