Maton B, Londono A, Sawrie S, Knowlton R, denHollander J, Kuzniecky R
UAB Epilepsy Center, 1719 6th Avenue South, CIRC 312, Birmingham, AL 35294-0021, USA.
J Neuroimaging. 2001 Apr;11(2):194-201. doi: 10.1111/j.1552-6569.2001.tb00033.x.
The authors investigate the reproducibility of metabolite signals measured with proton magnetic resonance spectroscopy (1H-MRS) acquired from the human hippocampus in controls and in a phantom. Two 1H-MRS studies separated by 3 weeks were performed in 8 healthy volunteers and in a phantom. N-acetyl compounds (NA), choline (Ch), and creatine (Cr) peak areas and ratios were measured and compared using percentage variation, and Pearson Correlation Coefficient at the level of every voxel, the level of 1 hippocampus (5 voxels), and the level of 2 hippocampi (10 voxels). Sensitivity for observing clinically significant between-session 1H-MRS changes was evaluated using the reliable change index. Reproducibility measures for metabolite peak areas were only moderately concordant with percentage variation ranging from 14% to 20% for NA, Cho, and Cr. Stability was much improved when NA ratios and sum of multiple voxels were considered. Between-session NA/(Cho + Cr) changes greater than 22%, 12%, and 10% in one given participant can be detected with a 90% confidence interval when considered at the single-voxel level, the level of a single hippocampus, or the level of both hippocampi, respectively. Left-right asymmetry indices showed similar and limited inter-hemispheric asymmetry in repeated examination. This study suggests that 1H-MRS reproducibility performance is adequate for the study and monitoring of human hippocampus function when NA ratios and the sum of multiple voxels are considered. Individual metabolite peaks and single-voxel measurements have low reproducibility at 1.5 T and should be used only with clearly established statistical parameters.
作者研究了在对照组和模型中,通过质子磁共振波谱(1H-MRS)从人脑海马体测量的代谢物信号的可重复性。对8名健康志愿者和一个模型进行了两项间隔3周的1H-MRS研究。测量并比较了N-乙酰化合物(NA)、胆碱(Ch)和肌酸(Cr)的峰面积及比率,使用百分比变化以及每个体素水平、1个海马体水平(5个体素)和2个海马体水平(10个体素)的Pearson相关系数进行比较。使用可靠变化指数评估观察1H-MRS会话间临床显著变化的敏感性。代谢物峰面积的可重复性测量结果与NA、Cho和Cr的14%至20%的百分比变化仅中度一致。当考虑NA比率和多个体素的总和时,稳定性有了很大提高。当在单个体素水平、单个海马体水平或两个海马体水平分别考虑时,在一名给定参与者中,会话间NA/(Cho + Cr)变化大于22%、12%和10%时,可在90%置信区间内检测到。左右不对称指数在重复检查中显示出相似且有限的半球间不对称。这项研究表明,当考虑NA比率和多个体素的总和时,1H-MRS的可重复性表现足以用于人类海马体功能的研究和监测。在1.5T时,单个代谢物峰和单个体素测量的可重复性较低,应仅在明确建立的统计参数下使用。