磨损碎屑诱导的骨溶解及翻修与聚乙烯体积磨损率的相关性:文献中8篇报告的综述

Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.

作者信息

Oparaugo P C, Clarke I C, Malchau H, Herberts P

机构信息

Department of Orthopaedic Surgery, Institute of Surgical Sciences, Sahlgrenska University Hospital, Göteborg, Sweden.

出版信息

Acta Orthop Scand. 2001 Feb;72(1):22-8. doi: 10.1080/000164701753606644.

Abstract

This survey focused on clinical reports of polyethylene wear and osteolysis in total hip replacements. With regard to documentation of clinical wear-rates, 57 publications were reduced to an analysis of 8 reports of THR series, including the incidence of osteolysis. A direct correlation was found among volumetric wear-rates, incidence of osteolysis and revision rates in THR concepts of the 1983-1987 era. As volumetric wear rate increased, the incidence of osteolysis and revision rates increased. With regard to our grading system for volumetric wear, with follow-up in the 4-15 year range, osteolysis was rare in group A (wear = 0-80 mm3/year), ranging from 6% to 31% in group B (wear 40-80 mm3/year) and from 21% to 100% in group C (wear > 140 mm3/year). With regard to cup design, the optimal low-wear group had mainly cemented polyethylene cups with 22 and 28 mm head sizes. The mid-wear group B had metal-backed cemented and uncemented cups, with 28 mm head size, and the high-risk group C had only uncemented, metal-backed cups, with the highest wear in the 32 mm head size. Less than 10 years of follow-up did not distinguish adequately between different designs of THR, except in a few cases which had early failures due to material or design deficiencies. Overall, the cemented all-polyethylene cup combined with the smaller ball head proved to be better.

摘要

这项调查聚焦于全髋关节置换术中聚乙烯磨损和骨溶解的临床报告。关于临床磨损率的记录,57篇出版物被缩减为对8篇全髋关节置换系列报告的分析,包括骨溶解的发生率。在1983 - 1987年期间的全髋关节置换概念中,发现体积磨损率、骨溶解发生率和翻修率之间存在直接关联。随着体积磨损率的增加,骨溶解发生率和翻修率也随之增加。关于我们的体积磨损分级系统,在4至15年的随访范围内,A组(磨损 = 0 - 80立方毫米/年)骨溶解罕见,B组(磨损40 - 80立方毫米/年)骨溶解发生率为6%至31%,C组(磨损 > 140立方毫米/年)骨溶解发生率为21%至100%。关于髋臼杯设计,最佳低磨损组主要是骨水泥固定的聚乙烯髋臼杯,股骨头尺寸为22毫米和28毫米。中等磨损的B组有金属背衬的骨水泥固定和非骨水泥固定髋臼杯,股骨头尺寸为28毫米,高风险的C组只有非骨水泥固定、金属背衬的髋臼杯,在32毫米股骨头尺寸时磨损最高。随访时间少于10年时,除了少数因材料或设计缺陷导致早期失败的病例外,无法充分区分不同设计的全髋关节置换。总体而言,骨水泥固定的全聚乙烯髋臼杯结合较小的球头被证明效果更好。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验