Intra- and interlaboratory variabilities of results obtained with the Quantiplex human immunodeficiency virus type 1 RNA bDNA assay, version 3.0.

作者信息

Kellogg J A, Atria P V, Sanders J C, Eyster M E

机构信息

Central Pennsylvania Alliance Laboratory, York, Pennsylvania, USA.

出版信息

Clin Diagn Lab Immunol. 2001 May;8(3):560-3. doi: 10.1128/CDLI.8.3.560-563.2001.

Abstract

Normal assay variation associated with bDNA tests for human immunodeficiency virus type 1 (HIV-1) RNA performed at two laboratories with different levels of test experience was investigated. Two 5-ml aliquots of blood in EDTA tubes were collected from each patient for whom the HIV-1 bDNA test was ordered. Blood was stored for no more than 4 h at room temperature prior to plasma separation. Plasma was stored at -70 degrees C until transported to the Central Pennsylvania Alliance Laboratory (CPAL; York, Pa.) and to the Hershey Medical Center (Hershey, Pa.) on dry ice. Samples were stored at < or =-70 degrees C at both laboratories prior to testing. Pools of negative (donor), low-HIV-1-RNA-positive, and high-HIV-1-RNA-positive plasma samples were also repeatedly tested at CPAL to determine both intra- and interrun variation. From 11 August 1999 until 14 September 2000, 448 patient specimens were analyzed in parallel at CPAL and Hershey. From 206 samples with results of > or =1,000 copies/ml at CPAL, 148 (72%) of the results varied by < or =0.20 log(10) when tested at Hershey and none varied by >0.50 log(10). However, of 242 specimens with results of <1,000 copies/ml at CPAL, 11 (5%) of the results varied by >0.50 log(10) when tested at Hershey. Of 38 aliquots of HIV-1 RNA pool negative samples included in 13 CPAL bDNA runs, 37 (97%) gave results of <50 copies/ml and 1 (3%) gave a result of 114 copies/ml. Low-positive HIV-1 RNA pool intrarun variation ranged from 0.06 to 0.26 log(10) while the maximum interrun variation was 0.52 log(10). High-positive HIV-1 RNA pool intrarun variation ranged from 0.04 to 0.32 log(10), while the maximum interrun variation was 0.55 log(10). In our patient population, a change in bDNA HIV-1 RNA results of < or =0.50 log(10) over time most likely represents normal laboratory test variation. However, a change of >0.50 log(10), especially if the results are >1,000 copies/ml, is likely to be significant.

摘要

研究了在两个具有不同检测经验水平的实验室中进行的1型人类免疫缺陷病毒(HIV-1)RNA的分支DNA(bDNA)检测相关的正常检测变异。从每位被要求进行HIV-1 bDNA检测的患者采集两份5毫升置于乙二胺四乙酸(EDTA)管中的血液样本。在进行血浆分离前,血液在室温下保存不超过4小时。血浆保存在-70℃,直至用干冰运送至宾夕法尼亚中部联盟实验室(CPAL;宾夕法尼亚州约克)和赫尔希医疗中心(宾夕法尼亚州赫尔希)。在两个实验室检测前,样本均保存在≤ -70℃。CPAL还对阴性(供体)、低HIV-1-RNA阳性和高HIV-1-RNA阳性血浆样本池进行了重复检测,以确定批内和批间变异。从1999年8月11日至2000年9月14日,CPAL和赫尔希对448份患者标本进行了平行分析。在CPAL检测结果≥1000拷贝/毫升的206份样本中,148份(72%)在赫尔希检测时结果变化≤0.20 log₁₀,且没有一份变化>0.50 log₁₀。然而,在CPAL检测结果<1000拷贝/毫升的242份标本中,11份(5%)在赫尔希检测时结果变化>0.50 log₁₀。在CPAL的13次bDNA检测中包含的38份HIV-1 RNA样本池阴性样本中,37份(97%)结果<50拷贝/毫升,1份(3%)结果为114拷贝/毫升。低阳性HIV-1 RNA样本池批内变异范围为0.06至0.26 log₁₀,而最大批间变异为0.52 log₁₀。高阳性HIV-1 RNA样本池批内变异范围为0.04至0.32 log₁₀,而最大批间变异为0.55 log₁₀。在我们的患者群体中,随着时间推移bDNA HIV-1 RNA结果变化≤0.50 log₁₀很可能代表正常的实验室检测变异。然而,变化>0.50 log₁₀,特别是如果结果>1000拷贝/毫升,则可能具有显著性。

相似文献

本文引用的文献

9
Biological and virologic characteristics of primary HIV infection.原发性HIV感染的生物学和病毒学特征。
Ann Intern Med. 1998 Apr 15;128(8):613-20. doi: 10.7326/0003-4819-128-8-199804150-00001.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验