A flow-through enzyme immunoassay has been developed for the screening of green coffee bean samples for ochratoxin A (OA) and was later used in a survey on OA in green coffee from different countries. The test has a sensitivity of 8 ng/g, and calculated recoveries ranged from 70 to 89% and from 86 to 95% for spiked and naturally contaminated samples, respectively. There were no significant differences in within-day and between-day assay performance (P > 0.05). Green coffee samples (15 Arabica and 7 Robusta) received from an international coffee trader were analyzed for intrinsic fungal contamination, screened for OA, and subsequently confirmed by high-performance liquid chromatography (HPLC). All 22 samples were contaminated by fungal species of the genus Aspergillus, while Penicillium species were isolated from a mere 13.6% of the total number of samples. Isolates were tested for their ability to produce OA, and only 3.9% were positive. There was no correlation between occurrence of OA-producing isolates and levels of OA in contaminated samples. Results of the screening procedure showed that 4 of the 22 samples were contaminated with 8 ng/g or higher. The HPLC method confirmed that the OA levels ranged from 27 to 168 ng/g. A fifth sample, which was shown to be negative during screening, had an OA concentration of 4 ng/g. There were no false negatives or positives recorded, and the flow-through enzyme immunoassay results correlated with those obtained by HPLC.

摘要

已开发出一种流通式酶免疫分析法,用于筛选生咖啡豆样品中的赭曲霉毒素A(OA),该方法随后被用于一项针对不同国家生咖啡中OA的调查。该检测方法的灵敏度为8 ng/g,加标样品和天然污染样品的计算回收率分别为70%至89%和86%至95%。日内和日间检测性能无显著差异(P>0.05)。对从国际咖啡贸易商处收到的生咖啡样品(15份阿拉比卡咖啡和7份罗布斯塔咖啡)进行了内在真菌污染分析、OA筛选,随后通过高效液相色谱法(HPLC)进行确认。所有22个样品均被曲霉菌属真菌污染,而仅13.6%的样品中分离出青霉菌属真菌。对分离菌株产生OA的能力进行了检测,只有3.9%呈阳性。产生OA的分离菌株的出现与污染样品中OA的水平之间没有相关性。筛选程序的结果表明,22个样品中有4个被污染,污染水平为8 ng/g或更高。HPLC方法确认OA水平在27至168 ng/g之间。第五个样品在筛选过程中显示为阴性,其OA浓度为4 ng/g。未记录到假阴性或假阳性结果,流通式酶免疫分析结果与HPLC获得的结果相关。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验