Singh Megha, Stoltz J F
Biomedical Engineering Division, Indian Institute of Technology, Madras 600036, India.
Clin Hemorheol Microcirc. 2002;26(1):1-7.
Erythrocyte aggregation and elongation index (EI) (deformability) are measured at temperatures ranging from 5 degrees C to 37 degrees C by aggregometer MA1, and diffractometer Rheodyne SSD and the LORCA, respectively. The test samples are prepared from blood obtained from healthy subjects in test tubes containing EDTA as an anticoagulant and prior to measurement are placed in a water bath for 30 min, maintained at respective temperatures. The aggregation process is given in terms of primary aggregation time and indices of aggregation. These show significant to highly significant changes with the increase of temperature compared to that at 5 degrees C. The EI increases with the increase of shear stress but shows significant decrease with the decrease of temperature.
红细胞聚集和伸长指数(EI)(变形性)分别通过MA1聚集仪、Rheodyne SSD衍射仪和LORCA在5摄氏度至37摄氏度的温度范围内进行测量。测试样本取自健康受试者的血液,置于含有乙二胺四乙酸作为抗凝剂的试管中,测量前在各自温度的水浴中放置30分钟。聚集过程以初级聚集时间和聚集指数表示。与5摄氏度时相比,随着温度升高,这些指标显示出显著到极显著的变化。EI随剪切应力增加而增加,但随温度降低而显著降低。