Nociti Júnior Francisco Humberto, Cesar Neto João Batista, Carvalho Marcelo Diniz, Sallum Enilson Antonio, Sallum Antonio Wilson
Department of Prosthodontics and Periodontics, School of Dentistry at Piracicaba, UNICAMP, São Paulo, Brazil.
J Periodontol. 2002 Sep;73(9):982-7. doi: 10.1902/jop.2002.73.9.982.
A negative influence of smoking on implant outcomes has been reported. This animal study investigated the influence of cigarette smoke on osseointegration and newly formed bone within implant threads.
Male Wistar rats were included in the study. After anesthesia, the tibiae surface was exposed and a screw-shaped titanium implant (4.0 mm in length; 2.2 mm in diameter) was placed bilaterally. The animals were randomly assigned to group 1, control, or group 2, intermittent cigarette smoke inhalation. The animals were sacrificed after 60 days and undecalcified sections obtained. The degree of bone-to-implant contact (BIC) and the bone area (BA) within the implant threads were measured in the cortical (zone A) and cancellous bone (zone B) areas.
A slight difference in the BIC was noted between the groups, but this was not statistically significant either in zone A or in zone B (Mann-Whitney test, P > 0.05). In contrast, the BA close to the implant significantly decreased in both zones for group 2 (84.73% +/- 4.77 versus 79.85% +/- 6.17, zone A in groups 1 and 2, respectively, and 32.01% +/- 6.62 versus 20.71% +/- 8.57, zone B in groups 1 and 2, respectively, P < 0.05).
Within the limits of the present study, intermittent cigarette smoke inhalation may result in a poor bone quality around titanium implants inserted in rats.
已有报道称吸烟会对种植体的效果产生负面影响。本动物研究调查了香烟烟雾对种植体骨结合以及种植体螺纹内新形成骨的影响。
雄性Wistar大鼠纳入本研究。麻醉后,暴露胫骨表面,并双侧植入一枚螺旋形钛种植体(长度4.0毫米;直径2.2毫米)。动物被随机分为1组(对照组)或2组(间歇性吸入香烟烟雾组)。60天后处死动物并获取不脱钙切片。测量皮质骨区域(A区)和松质骨区域(B区)内种植体与骨的接触程度(BIC)以及种植体螺纹内的骨面积(BA)。
两组之间的BIC存在细微差异,但在A区或B区均无统计学意义(曼-惠特尼检验,P>0.05)。相比之下,2组两个区域中靠近种植体的BA均显著降低(1组和2组A区分别为84.73%±4.77和79.85%±6.17,1组和2组B区分别为32.01%±6.62和20.71%±8.57,P<0.05)。
在本研究范围内,间歇性吸入香烟烟雾可能导致大鼠植入的钛种植体周围骨质量较差。