We sought to develop a direct, noninvasive measurement of tear oxygen tension behind soft contact lenses, and to use the tear oxygen tension data to determine if subjects with greater comeal oxygen consumption experience more comeal edema under hypoxic conditions. The relationship between tear oxygen tension and comeal thickness was also analyzed to determine if thicker comeas have higher metabolic rates.
Tear oxygen tension measurement was based on the quenching of a phosphorescent dye by oxygen. By coating a soft contact lens with the dye and placing it in the eye, the rate of decay of phosphorescence could be measured and the tear oxygen tension calculated. Corneal oxygen consumption could then be calculated from the tear oxygen tension. Central corneal swelling was measured after 3 hours of hypoxia induced by contact lens wear under closed-eye conditions.
Seven right eyes of seven subjects were tested. Baseline central corneal thickness ranged from 517 to 616 microns. After 3 hours of hypoxia, central corneal swelling ranged from 24.5 to 74.3 microns (3.9% to 13.4%). Steady-state open-eye tear PO2 behind the lens varied between 42.7 and 67.1 torr Pearson correlation suggested possible inverse relationship between open-eye tear oxygen tension and central comeal swelling during hypoxia (r = -0.711, p = 0.0734).
Phosphorescent-based measurements provided a measure of tear oxygen tension in human beings. Low tear film oxygen tensions (high corneal metabolic demand) appeared to predict greater amounts of swelling in subjects' corneas. No relation was found between corneal thickness and tear oxygen tension, suggesting that epithelial and endothelial metabolic rates are more important than stromal thickness in determination of comeal oxygen demand.
我们试图开发一种直接、无创的方法来测量软性隐形眼镜后泪液的氧张力,并利用泪液氧张力数据来确定在缺氧条件下角膜氧消耗较高的受试者是否会经历更多的角膜水肿。还分析了泪液氧张力与角膜厚度之间的关系,以确定较厚的角膜是否具有更高的代谢率。
泪液氧张力测量基于氧对磷光染料的猝灭作用。通过在软性隐形眼镜上涂覆染料并将其置于眼中,可以测量磷光衰减速率并计算泪液氧张力。然后可以根据泪液氧张力计算角膜氧消耗。在闭眼条件下佩戴隐形眼镜诱导缺氧3小时后,测量中央角膜肿胀情况。
对7名受试者的7只右眼进行了测试。基线中央角膜厚度范围为517至616微米。缺氧3小时后,中央角膜肿胀范围为24.5至74.3微米(3.9%至13.4%)。镜片后稳态睁眼泪液PO2在42.7至67.1托之间。Pearson相关性分析表明,缺氧期间睁眼泪液氧张力与中央角膜肿胀之间可能存在负相关(r = -0.711,p = 0.0734)。
基于磷光的测量方法提供了一种测量人类泪液氧张力的方法。低泪膜氧张力(高角膜代谢需求)似乎预示着受试者角膜肿胀程度更高。未发现角膜厚度与泪液氧张力之间存在关联,这表明在确定角膜氧需求方面,上皮和内皮的代谢率比基质厚度更重要。