Suppr超能文献

一种用于人促甲状腺激素的灵敏且精确的放射免疫测定法。

A sensitive and precise radioimmunoassay for human thyroid-stimulating hormone.

作者信息

Pekary A E, Hershman J M, Parlow A F

出版信息

J Clin Endocrinol Metab. 1975 Oct;41(4):676-84. doi: 10.1210/jcem-41-4-676.

Abstract

A high-sensitivity radioimmunoassay for human thyroid-stimulating hormone (hTSH) has been developed utilizing a highly specific rabbit antibody (developed by AFP) to hTSH with an affinity constant of 4.4 x 10(11) M-1. Optimal conditions which minimized both 125I-hTSH radiation damage and 125I dissociation included storage at -60 C in 0.25% albumin. Repetitive freezing and thawing did not cause loss of structural integrity or of full immunochemical reactivity of 125I-hTSH. Effects of human and calf sera on the precipitation of first antibody-bound 125I-hTSH by second antibody have been tabulated; the addition of TSH-free human serum to the standard curve is necessary to compensate for the serum effect. The minimum detectable amount of TSH in the new assay at a 1:1,000,000 final dilution of the hTSH antibody is 0.02 muU/tube. The mean normal hTSH value of 1.5 +/- 1.0 muU/ml (mean +/- SD) fell within the central one-third of the logit (B/Bo) plot where antigen concentrations are measured with highest precision. This assay gives good precision and reproducibility of measurements throughout the normal range of serum TSH concentrations.

摘要

利用一种对人促甲状腺激素(hTSH)具有高度特异性的兔抗体(由甲胎蛋白研发),开发了一种高灵敏度放射免疫分析法来检测人促甲状腺激素,该抗体的亲和常数为4.4×10¹¹M⁻¹。将¹²⁵I-hTSH的辐射损伤和¹²⁵I解离降至最低的最佳条件包括在-60℃下于0.25%白蛋白中储存。反复冻融不会导致¹²⁵I-hTSH的结构完整性丧失或完全免疫化学反应性丧失。已将人和小牛血清对第二抗体沉淀第一抗体结合的¹²⁵I-hTSH的影响制成表格;向标准曲线中加入无TSH的人血清对于补偿血清效应是必要的。在hTSH抗体最终稀释至1:1,000,000时,新分析方法中TSH的最低检测量为0.02μU/管。正常hTSH的平均数值为1.5±1.0μU/ml(平均值±标准差),落在对数概率(B/Bo)图的中间三分之一范围内,在此范围内抗原浓度的测量精度最高。该分析方法在血清TSH浓度的整个正常范围内具有良好的测量精度和可重复性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验