Suppr超能文献

用于成像5-羟色胺转运体的五种正电子发射断层显像(PET)放射性示踪剂在非人灵长类动物中的比较评估:[11C]McN 5652、[11C]ADAM、[11C]DASB、[11C]DAPA和[11C]AFM。

Comparative evaluation in nonhuman primates of five PET radiotracers for imaging the serotonin transporters: [11C]McN 5652, [11C]ADAM, [11C]DASB, [11C]DAPA, and [11C]AFM.

作者信息

Huang Yiyun, Hwang Dah-Ren, Narendran Raj, Sudo Yasuhiko, Chatterjee Rano, Bae Sung-A, Mawlawi Osama, Kegeles Lawrence S, Wilson Alan A, Kung Hank F, Laruelle Marc

机构信息

Department of Psychiatry, Columbia University College of Physicians and Surgeons, New York, NY, USA.

出版信息

J Cereb Blood Flow Metab. 2002 Nov;22(11):1377-98. doi: 10.1097/01.WCB.0000040948.67415.05.

Abstract

The recent introduction of a number of new radiotracers suitable for imaging the serotonin transporters (SERT) has radically changed the field of SERT imaging. Whereas, until recently, only one selective SERT radiotracer was available ([11C]McN 5652) for SERT imaging with positron emission tomography (PET), several new C-11-labeled radiotracers of the -dimethyl-2-(arylthio)benzylamine class have been described as appropriate imaging agents for the SERT. The aim of this study was to conduct a comparative evaluation of four of the most promising agents in this class ([11C]ADAM, [11C]DASB, [11C]DAPA, and [11C]AFM) with the reference tracer [11C]McN 5652 under standardized experimental conditions. This evaluation included in vitro measurements of affinity and lipophilicity, and in vivo PET imaging experiments in baboons. In vitro, DASB displayed significantly lower affinity for SERT than the other four tracers. In the blood, [11C]DASB and [11C]AFM display faster clearance and higher free fractions. Brain uptake was analyzed with kinetic modeling using a one-tissue compartment model and the metabolite-corrected arterial input function. The kinetic uptake of [11C]DASB was significantly faster compared with the other compounds, and the scan duration required to derive time-independent estimates of regional distribution volumes was shorter. [11C]DAPA exhibited the slowest brain kinetic. Regional-specific-to-nonspecific equilibrium partition coefficient (V3") was the highest for [11C]AFM, followed by [11C]DASB and [11C]DAPA, which in turn provided higher V3" values than [11C]ADAM and [11C]McN 5652. From these experiments, two ligands emerged as superior radiotracers that provide a significant improvement over [11C]McN 5652 for PET imaging of SERT: [11C]DASB, because it enables the measurement of SERT availability in a shorter scanning time, and [11C]AFM, because its higher signal-to-noise ratios provide a more reliable measurement of SERT availability in brain regions with relatively low density of SERT, such as in the limbic system.

摘要

近期引入的多种适用于成像5-羟色胺转运体(SERT)的新型放射性示踪剂,已彻底改变了SERT成像领域。直到最近,正电子发射断层扫描(PET)用于SERT成像时,仅有一种选择性SERT放射性示踪剂([11C]McN 5652)可用,而现在已描述了几种新型的 -二甲基-2-(芳硫基)苄胺类C-11标记放射性示踪剂,作为SERT的合适成像剂。本研究的目的是在标准化实验条件下,将该类中最具前景的四种试剂([11C]ADAM、[11C]DASB、[11C]DAPA和[11C]AFM)与参考示踪剂[11C]McN 5652进行比较评估。该评估包括亲和力和亲脂性的体外测量,以及在狒狒身上进行的体内PET成像实验。在体外,DASB对SERT的亲和力显著低于其他四种示踪剂。在血液中,[11C]DASB和[11C]AFM清除更快,游离分数更高。使用单组织隔室模型和代谢物校正的动脉输入函数,通过动力学建模分析脑摄取。与其他化合物相比,[11C]DASB的动力学摄取显著更快,获得区域分布体积与时间无关估计所需的扫描持续时间更短。[11C]DAPA表现出最慢的脑动力学。区域特异性与非特异性平衡分配系数(V3")对于[11C]AFM最高,其次是[11C]DASB和[11C]DAPA,它们依次提供比[11C]ADAM和[11C]McN 5652更高的V3"值。从这些实验中,出现了两种作为卓越放射性示踪剂的配体,它们在PET成像SERT方面比[11C]McN 5652有显著改进:[11C]DASB,因为它能在更短的扫描时间内测量SERT可用性;[11C]AFM,因为其更高的信噪比能在SERT密度相对较低的脑区(如边缘系统)更可靠地测量SERT可用性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验