Suppr超能文献

使用荧光标记抗原定量测定法对HIV-1 p24和SIV p27进行实时定量。

Real-time quantitation of HIV-1 p24 and SIV p27 using fluorescence-linked antigen quantification assays.

作者信息

Hayden Matthew S, Palacios Emil H, Grant Robert M

机构信息

Gladstone Institute of Virology and Immunology, San Francisco, CA, USA.

出版信息

AIDS. 2003 Mar 7;17(4):629-31. doi: 10.1097/00002030-200303070-00021.

Abstract

We developed fluorescence-linked antigen quantification (FLAQ) assays for HIV-1 and SIV antigen quantitation. The assays utilize polystyrene microspheres coated with monoclonal antibodies against HIV-1 Gag p24 or SIV Gag p27, which are incubated with unknown samples, flourochrome-conjugated detector antibody, and lysing agent. The fluorescence of individual microspheres is measured using flow cytometry. The speed, simplicity, and wide dynamic range of FIAQ assays makes them superior to enzyme-linked immunosorbent assays for many applications performed in research laboratories.

摘要

我们开发了用于HIV-1和SIV抗原定量的荧光连接抗原定量(FLAQ)检测方法。这些检测方法利用包被有抗HIV-1 Gag p24或SIV Gag p27单克隆抗体的聚苯乙烯微球,将其与未知样品、荧光素缀合的检测抗体和裂解剂一起孵育。使用流式细胞术测量单个微球的荧光。FLAQ检测方法的速度、简便性和宽动态范围使其在研究实验室进行的许多应用中优于酶联免疫吸附测定。