Suppr超能文献

使用新型自动控制压力和流量的冲洗/抽吸系统与标准冲洗相比的经尿道输尿管肾镜碎石术:一项随机试点研究。

Transurethral ureterorenolithotripsy using new automated irrigation/suction system controlling pressure and flow compared with standard irrigation: a randomized pilot study.

作者信息

Lechevallier Eric, Luciani Martin, Nahon Olivier, Lay Franck, Coulange Christian

机构信息

Department of Urology, Hôpital Salvator, Marseille, France.

出版信息

J Endourol. 2003 Mar;17(2):97-101. doi: 10.1089/08927790360587423.

Abstract

PURPOSE

To compare in a random fashion an automated irrigation/suction pump system with the standard pressurized technique during transurethral ureterorenolithotripsy.

PATIENTS AND METHODS

Between July 2001 and December 2001, 47 patients were prospectively included. Prior to randomization, rigid instruments were allocated to 25 patients (group R) and flexible instruments to 22 patients (group F) according to stone location. The groups R and F were then randomized separately, and the pressurized technique was employed in groups R1 and F1, while the automated system was employed in groups R2 and F2. Operative time, amount of liquid consumed, and stone-free rate at the end of the procedure were analyzed.

RESULTS

For the entire series, ureteroscopy time using the automated system (mean 42 +/- 17[SD] minutes; range 15-90 minutes) was 35% less than with the pressurized technique (mean 65 +/- 25 minutes; range 20-135 minutes) (P = 0.04 Wilcoxon score). The stone-free rate was significantly higher in groups R2 + F2 (92%) than in groups R1 + F1 (69%) (P = 0.048).

CONCLUSION

With the ENDO FMS UROLOGY system, there was a significant reduction in the mean ureteroscopy time: 32% less with the rigid instrument and 53% less with the flexible instrument. This seems to be attributable to a wider working space and highly improved visibility. The integrated suction at constant flow allows efficient evacuation of stone fragments while limiting cavity pressure. These results, obtained on 47 patients, should be confirmed by larger randomized studies.

摘要

目的

在经尿道输尿管肾镜碎石术期间,以随机方式比较自动冲洗/吸引泵系统与标准加压技术。

患者与方法

2001年7月至2001年12月,前瞻性纳入47例患者。随机分组前,根据结石位置将硬性器械分配给25例患者(R组),软性器械分配给22例患者(F组)。然后R组和F组分别随机分组,R1组和F1组采用加压技术,R2组和F2组采用自动系统。分析手术时间、液体消耗量以及手术结束时的结石清除率。

结果

对于整个系列,使用自动系统的输尿管镜检查时间(平均42±17[标准差]分钟;范围15 - 90分钟)比加压技术(平均65±25分钟;范围20 - 135分钟)少35%(P = 0.04,Wilcoxon评分)。R2 + F2组的结石清除率(92%)显著高于R1 + F1组(69%)(P = 0.048)。

结论

使用ENDO FMS泌尿外科系统,平均输尿管镜检查时间显著减少:使用硬性器械时减少32%,使用软性器械时减少53%。这似乎归因于更宽的工作空间和显著提高的视野。恒定流量的集成吸引可有效排出结石碎片,同时限制腔室压力。在47例患者中获得的这些结果,应通过更大规模的随机研究加以证实。