Suppr超能文献

使用FlexMaster和HERO 642旋转镍钛器械进行根管预备的对比研究。

A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments.

作者信息

Hülsmann M, Gressmann G, Schäfers F

机构信息

Department of Operative Dentistry, Preventive Dentistry and Periodontology, University of Göttingen, Germany.

出版信息

Int Endod J. 2003 May;36(5):358-66. doi: 10.1046/j.1365-2591.2003.00664.x.

Abstract

AIM

To compare several parameters of root canal preparation using two different rotary nickel-titanium (Ni-Ti) instruments: FlexMaster (VDW, Munich, Germany) and HERO 642 (Micro-Mega, Besançon, France).

METHODOLOGY

Fifty extracted human mandibular molars with root canal curvatures between 20 and 40 degrees were embedded into a muffle system. All root canals were prepared to size 45 using a high-torque motor with two different Ni-Ti instruments, FlexMaster and HERO 642. In both groups, irrigation was performed with 2 mL NaOCl (3%) after each instrument size. RC-Prep (Premier, Philadelphia, USA) was used as a chelating agent with each instrument. The following parameters were evaluated: straightening of curved root canals, postoperative root canal diameter, working safety (file fractures, perforations, apical blockages, loss of working length), cleaning ability and working time. Statistical analysis was performed using the Wilcoxon's test (P < 0.05) for straightening and Fishers's exact test (P < 0.05) for comparison of cross-sections, contact between pre- and postoperative diameter, root canal cleanliness and working time.

RESULTS

Both Ni-Ti systems maintained the curvature well: the mean degree of straightening was 0.6 degrees for FlexMaster and 0.5 degrees for HERO 642. One file was fractured with the FlexMaster system, but further procedural incidents were not recorded. Following preparation with FlexMaster, 18% of the root canals had a round diameter, 53% an oval diameter and 29% an irregular diameter; HERO 642 preparations resulted in a round diameter in 25%, oval shape in 47% and irregular cross-sections in 28% of the cases. Mean working time was shorter for HERO 642 (66.0 s) than for FlexMaster (71.1 s). Cleanliness of the root canal walls was investigated under the SEM using 5-score indices for debris and smear layer. For debris, HERO 642 and FlexMaster achieved 73 and 70% scores of 1 and 2, respectively. The results for smear layer were similar: HERO 642 and FlexMaster achieved 33 and 26% scores of 1 and 2, respectively. Significant differences between the two systems were not detected for any of the parameters evaluated.

CONCLUSIONS

Both systems respected original root canal curvature well and were safe. Both systems failed to remove debris and smear layer in the majority of the cases.

摘要

目的

比较使用两种不同的旋转镍钛(Ni-Ti)器械:FlexMaster(德国慕尼黑VDW公司)和HERO 642(法国贝桑松Micro-Mega公司)进行根管预备的几个参数。

方法

将50颗根管弯曲度在20至40度之间的拔除的人类下颌磨牙嵌入马弗炉系统。使用高扭矩马达和两种不同的Ni-Ti器械FlexMaster和HERO 642将所有根管预备到45号。在两组中,每种器械型号使用后均用2 mL次氯酸钠(3%)冲洗。每种器械均使用RC-Prep(美国费城Premier公司)作为螯合剂。评估以下参数:弯曲根管的伸直情况、术后根管直径、工作安全性(锉针折断、穿孔、根尖堵塞、工作长度丧失)、清洁能力和工作时间。使用Wilcoxon检验(P < 0.05)对伸直情况进行统计分析,使用Fisher精确检验(P < 0.05)对横截面比较、术前和术后直径之间的接触、根管清洁度和工作时间进行统计分析。

结果

两种Ni-Ti系统均能很好地保持根管弯曲度:FlexMaster的平均伸直度为0.6度,HERO 642为0.5度。FlexMaster系统有一根锉针折断,但未记录到进一步的操作事故。使用FlexMaster预备后,18%的根管直径呈圆形,53%呈椭圆形,29%呈不规则形;HERO 642预备的病例中,25%的根管直径呈圆形,47%呈椭圆形,28%呈不规则横截面。HERO 642的平均工作时间(66.0秒)比FlexMaster(71.1秒)短。使用5分制指数在扫描电子显微镜下研究根管壁的清洁度,以评估碎屑和玷污层情况。对于碎屑,HERO 642和FlexMaster分别有73%和70%的得分在1分和2分。玷污层的结果类似:HERO 642和FlexMaster分别有33%和26%的得分在1分和2分。在所评估的任何参数中,未检测到两种系统之间存在显著差异。

结论

两种系统均能很好地保持原始根管弯曲度且安全。在大多数情况下,两种系统均未能去除碎屑和玷污层。