Suppr超能文献

切片到容积配准及其在介入性磁共振成像引导下前列腺癌射频热消融中的潜在应用。

Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer.

作者信息

Fei Baowei, Duerk Jeffrey L, Boll Daniel T, Lewin Jonathan S, Wilson David L

机构信息

Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.

出版信息

IEEE Trans Med Imaging. 2003 Apr;22(4):515-25. doi: 10.1109/TMI.2003.809078.

Abstract

In this study, we registered live-time interventional magnetic resonance imaging (iMRI) slices with a previously obtained high-resolution MRI volume that in turn can be registered with a variety of functional images, e.g., PET, SPECT, for tumor targeting. We created and evaluated a slice-to-volume (SV) registration algorithm with special features for its potential use in iMRI-guided radio-frequency (RF) thermal ablation of prostate cancer. The algorithm features included a multiresolution approach, two similarity measures, and automatic restarting to avoid local minima. Imaging experiments were performed on volunteers using a conventional 1.5-T MR scanner and a clinical 0.2-T C-arm iMRI system under realistic conditions. Both high-resolution MR volumes and actual iMRI image slices were acquired from the same volunteers. Actual and simulated iMRI images were used to test the dependence of SV registration on image noise, receive coil inhomogeneity, and RF needle artifacts. To quantitatively assess registration, we calculated the mean voxel displacement over a volume of interest between SV registration and volume-to-volume registration, which was previously shown to be quite accurate. More than 800 registration experiments were performed. For transverse image slices covering the prostate, the SV registration algorithm was 100% successful with an error of <2 mm, and the average and standard deviation was only 0.4 mm +/- 0.2 mm. Visualizations such as combined sector display and contour overlay showed excellent registration of the prostate and other organs throughout the pelvis. Error was greater when an image slice was obtained at other orientations and positions, mostly because of inconsistent image content such as that from variable rectal and bladder filling. These preliminary experiments indicate that MR SV registration is sufficiently accurate to aid image-guided therapy.

摘要

在本研究中,我们将实时介入磁共振成像(iMRI)切片与先前获取的高分辨率MRI容积进行配准,而该容积又可与各种功能图像(如PET、SPECT)配准,用于肿瘤靶向。我们创建并评估了一种切片到容积(SV)配准算法,该算法具有特殊特性,可用于iMRI引导的前列腺癌射频(RF)热消融。该算法的特性包括多分辨率方法、两种相似性度量以及自动重启以避免局部最小值。在实际条件下,使用传统的1.5-T MR扫描仪和临床0.2-T C型臂iMRI系统对志愿者进行成像实验。从同一志愿者身上获取高分辨率MR容积和实际iMRI图像切片。使用实际和模拟的iMRI图像来测试SV配准对图像噪声、接收线圈不均匀性和RF针伪影的依赖性。为了定量评估配准情况,我们计算了SV配准与容积到容积配准之间感兴趣容积内的平均体素位移,先前已证明容积到容积配准相当准确。进行了800多次配准实验。对于覆盖前列腺的横向图像切片,SV配准算法成功率为100%,误差<2 mm,平均误差和标准差仅为0.4 mm±0.2 mm。诸如组合扇形显示和轮廓叠加等可视化显示了整个骨盆中前列腺和其他器官的良好配准。当在其他方向和位置获取图像切片时,误差更大,主要是因为图像内容不一致,如直肠和膀胱充盈情况不同。这些初步实验表明,MR SV配准足够准确,有助于图像引导治疗。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验