Suppr超能文献

Laterality of the performance of glaucoma mass screening using frequency-doubling technology.

作者信息

Tatemichi Masayuki, Nakano Tadashi, Tanaka Katsutoshi, Hayashi Takeshi, Nawa Takeshi, Iwasaki Akio, Miyamoto Toshiaki, Hiro Hisanori, Sugita Minoru

机构信息

Department of Environmental and Occupational Health, Toho University School of Medicine, 5-21-16 Omori-nishi, Otaku, Tokyo 143-8540, Japan.

出版信息

J Glaucoma. 2003 Jun;12(3):221-5. doi: 10.1097/00061198-200306000-00007.

Abstract

PURPOSE

This study investigated laterality during the performance of glaucoma mass screening with a frequency-doubling technology perimetry test.

MATERIALS AND METHODS

A frequency-doubling technology screening mode (C-20-1, version 2.6) test was performed on both eyes of 14,784 persons. Subjects with visual field abnormalities detected by the frequency-doubling technology test or with fixation error underwent retesting without a specified interval for rest. Consequently, 206 subjects who fulfilled the screening criteria of the frequency-doubling technology-based glaucoma screening protocol [FDT-GSP(+)] were further investigated using the Humphrey visual field analyzer (30-2). As a result, 74 right eyes and 57 left eyes were shown to have definite glaucoma.

RESULTS

Frequency-doubling technology data for the left eye demonstrated a significantly (P<0.001) higher rate of artifacts, such as no reproducibility of results between the first and second tests (left/right: 2.4%/1.7%) as well as fixation errors (left/right: 2.8%/1.0%). The false-positive rate of the FDT-GSP for glaucoma was more than 1.5-fold higher in the left eye than in the right eye (16.3%/9.8%). In the case that either eye exhibited FDT-GSP(+), the positive predictive value of the FDT-GSP for definite glaucoma in the left eye was almost half of that in the right eye (28.4% vs. 53.8%). Specificity of the FDT-GSP for detection of definite glaucoma also exhibited a lower trend (P = 0.097) in the left eye (44.6%) than in the right eye (55.3%), but the sensitivity of the test was similar in both eyes (91.2% vs. 90.5%, respectively).

CONCLUSIONS

When frequency-doubling technology-based mass screening is performed on the general population, performance is lower for the left eye than for the right eye. This performance disparity is likely to be primarily associated with a difference in specificity.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验