Piotin Michel, Iijima Akira, Wada Hajime, Moret Jacques
Department of Interventional Neuroradiology, Fondation Rothschild, Paris, France.
AJNR Am J Neuroradiol. 2003 Aug;24(7):1446-8.
Nine embolization experiments of a silicone aneurysm model were conducted by using helical and complex-shaped coils. Coils were introduced up to the point when the adjunct of a supplementary coil caused protrusion into the parent vessel. Packing ratios (volume of coils-aneurysm volume) ranged between 31% and 38%. Optimal packing was achieved with complex-shaped coils used in a concentric fashion. The complex-shaped coils allowed a better aneurysm filling than did helical coils.