Weatherburn Gwyneth C, Ridout Deborah, Strickland Nicola H, Robins Peter, Glastonbury Christine M, Curati Walter, Harvey Chris, Shadbolt Clair
Health Economics Research Group, Brunel University, Uxbridge, UK.
Eur J Radiol. 2003 Sep;47(3):206-14. doi: 10.1016/s0720-048x(02)00214-0.
The aim of this study was to determine whether the accuracy of diagnosis of a spectrum of chest pathology was affected by the imaging technique used, and to compare conventional film/screen, hard copy computed (phosphor plate) radiography (CR) and soft copy CR (PACS) images.
For each of 44 patients who had a CT examination of the thorax, PA and lateral chest radiographs were produced using conventional film, hard copy CR and soft copy PACS images. Five radiologists independently scored all images for the presence of abnormalities. The data were analysed in two stages using the result of the CT scan as the reference standard diagnosis: firstly, to investigate differences in abnormality scores between image modalities and observers using ROC analysis; secondly, to investigate the agreement of the diagnoses with the reference standard by the analysis of kappa scores.
The ROC analyses and comparison of kappa scores showed no differences between image modalities (P=0.72, P=0.87), but highly significant differences between observers (P<0.001, P=0.003).
The detection of chest lesions did not vary between conventional film, CR hard copy and PACS soft copy images. For all three image types, there were statistically significant differences between observers.
本研究旨在确定胸部一系列病变的诊断准确性是否受所使用的成像技术影响,并比较传统胶片/屏片、硬拷贝计算机(磷光板)X线摄影(CR)和软拷贝CR(PACS)图像。
对44例接受胸部CT检查的患者,分别使用传统胶片、硬拷贝CR和软拷贝PACS图像生成后前位和侧位胸部X线片。五名放射科医生独立对所有图像的异常情况进行评分。以CT扫描结果作为参考标准诊断,分两个阶段对数据进行分析:首先,使用ROC分析研究图像模式和观察者之间异常评分的差异;其次,通过分析kappa评分研究诊断与参考标准的一致性。
ROC分析和kappa评分比较显示图像模式之间无差异(P = 0.72,P = 0.87),但观察者之间存在高度显著差异(P < 0.001,P = 0.003)。
传统胶片、CR硬拷贝和PACS软拷贝图像在胸部病变检测方面无差异。对于所有三种图像类型,观察者之间存在统计学显著差异。