Suppr超能文献

使用商用高分辨率X射线计算机断层扫描仪对中耳听骨链进行三维建模。

Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner.

作者信息

Decraemer W F, Dirckx J J J, Funnell W R J

机构信息

Biomedical Physics, University of Antwerp, RUCA, Antwerpen, Belgium.

出版信息

J Assoc Res Otolaryngol. 2003 Jun;4(2):250-63. doi: 10.1007/s10162-002-3030-x.

Abstract

The quantitative measurement of the three-dimensional (3-D) anatomy of the ear is of great importance in the making of teaching models and the design of mathematical models of parts of the ear, and also for the interpretation and presentation of experimental results. This article describes how we used virtual sections from a commercial high-resolution X-ray computed tomography (CT) scanner to make realistic 3-D anatomical models for various applications in our middle-ear research. The important problem of registration of the 3-D model within the experimental reference frame is discussed. The commercial X-ray CT apparatus is also compared with X-ray CT using synchrotron radiation, with magnetic resonance microscopy, with fluorescence optical sectioning, and with physical (histological) serial sections.

摘要

耳朵三维(3-D)解剖结构的定量测量对于制作教学模型、设计耳部各部分的数学模型以及解释和展示实验结果都非常重要。本文描述了我们如何使用商业高分辨率X射线计算机断层扫描(CT)扫描仪的虚拟切片,为中耳研究中的各种应用制作逼真的3-D解剖模型。讨论了3-D模型在实验参考框架内配准的重要问题。还将商业X射线CT设备与使用同步辐射的X射线CT、磁共振显微镜、荧光光学切片以及物理(组织学)连续切片进行了比较。

相似文献

1
Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner.
J Assoc Res Otolaryngol. 2003 Jun;4(2):250-63. doi: 10.1007/s10162-002-3030-x.
2
Open access high-resolution 3D morphology models of cat, gerbil, rabbit, rat and human ossicular chains.
Hear Res. 2012 Feb;284(1-2):1-5. doi: 10.1016/j.heares.2011.12.004. Epub 2011 Dec 13.
3
Improved middle-ear soft-tissue visualization using synchrotron radiation phase-contrast imaging.
Hear Res. 2017 Oct;354:1-8. doi: 10.1016/j.heares.2017.08.001. Epub 2017 Aug 5.
4
Middle ear imaging using virtual endoscopy and its application in patients with ossicular chain anomaly.
ORL J Otorhinolaryngol Relat Spec. 2000 Nov-Dec;62(6):316-20. doi: 10.1159/000027776.
5
[Three-dimensional CT of the ossicles of the middle ear].
Nihon Jibiinkoka Gakkai Kaiho. 1995 Feb;98(2):245-53. doi: 10.3950/jibiinkoka.98.245.
7
Virtual CT otoscopy of the middle ear and ossicles in dogs.
Vet Radiol Ultrasound. 2008 Nov-Dec;49(6):545-50. doi: 10.1111/j.1740-8261.2008.00428.x.
8
Realistic 3D computer model of the gerbil middle ear, featuring accurate morphology of bone and soft tissue structures.
J Assoc Res Otolaryngol. 2011 Dec;12(6):681-96. doi: 10.1007/s10162-011-0281-4. Epub 2011 Jul 13.
10
[On the clinical application of spiral CT three-dimensional reconstruction of middle ear ossicles].
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2012 Oct;26(19):865-7.

引用本文的文献

4
Validated Ossicular Measurements on High-Resolution Computed Tomography (CT) in Live and Cadaveric Temporal Bones.
Cureus. 2022 Feb 20;14(2):e22410. doi: 10.7759/cureus.22410. eCollection 2022 Feb.
5
Evolution of Middle Ear Modelling Techniques: A Review.
Cureus. 2021 Dec 30;13(12):e20829. doi: 10.7759/cureus.20829. eCollection 2021 Dec.
6
Micro-CT of the human ossicular chain: Statistical shape modeling and implications for otologic surgery.
J Anat. 2021 Oct;239(4):771-781. doi: 10.1111/joa.13457. Epub 2021 May 31.
9
Three-dimensional vibration of the malleus and incus in the living gerbil.
J Assoc Res Otolaryngol. 2014 Aug;15(4):483-510. doi: 10.1007/s10162-014-0452-1. Epub 2014 Apr 2.
10
Three-dimensional histological specimen preparation for accurate imaging and spatial reconstruction of the middle and inner ear.
Int J Comput Assist Radiol Surg. 2013 Jul;8(4):481-509. doi: 10.1007/s11548-013-0825-7. Epub 2013 Apr 30.

本文引用的文献

1
Deformable templates using large deformation kinematics.
IEEE Trans Image Process. 1996;5(10):1435-47. doi: 10.1109/83.536892.
2
A VRML-based anatomical visualization tool for medical education.
IEEE Trans Inf Technol Biomed. 1998 Jun;2(2):55-61. doi: 10.1109/4233.720523.
3
Virtual temporal bone: creation and application of a new computer-based teaching tool.
Otolaryngol Head Neck Surg. 2000 Feb;122(2):168-73. doi: 10.1016/S0194-5998(00)70234-8.
4
Deformable models in medical image analysis: a survey.
Med Image Anal. 1996 Jun;1(2):91-108. doi: 10.1016/s1361-8415(96)80007-7.
5
Desktop X-ray microscopy and microtomography.
J Microsc. 1998 Aug;191(2):151-158.
6
Automated image registration: I. General methods and intrasubject, intramodality validation.
J Comput Assist Tomogr. 1998 Jan-Feb;22(1):139-52. doi: 10.1097/00004728-199801000-00027.
7
Watershed-based segmentation of 3D MR data for volume quantization.
Magn Reson Imaging. 1997;15(6):679-88. doi: 10.1016/s0730-725x(97)00033-7.
8
Three-dimensional reconstruction of the cochlea from two-dimensional images of optical sections.
Comput Med Imaging Graph. 1995 Sep-Oct;19(5):377-84. doi: 10.1016/0895-6111(95)00034-8.
9
Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens.
J Microsc. 1993 Jun;170(Pt 3):229-36. doi: 10.1111/j.1365-2818.1993.tb03346.x.
10
Imaging the cochlea by magnetic resonance microscopy.
Hear Res. 1994 May;75(1-2):75-80. doi: 10.1016/0378-5955(94)90058-2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验