• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Performance of laboratories measuring silica in the Proficiency Analytical Testing program.

作者信息

Shulman S A, Groff J H, Abell M T

机构信息

National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, OH 45226.

出版信息

Am Ind Hyg Assoc J. 1992 Jan;53(1):49-56. doi: 10.1080/15298669291359294.

DOI:10.1080/15298669291359294
PMID:1317092
Abstract

A statistical study was performed on the results reported by laboratories analyzing silica samples in the first 101 rounds of the Proficiency Analytical Testing (PAT) program. Five laboratories participated in the first round of the PAT program in 1972, and participation grew to 130 laboratories before falling to 105 in Round 101. The laboratories use all three of the major methods of analysis: colorimetry, x-ray diffractometry, and infrared spectroscopy. The objectives of the study were to determine bias between methods, the variability associated with the methods, and any changes in bias or variability caused by a number of factors. The colorimetric method has consistently given the lowest results, particularly at higher loadings. X-ray diffractometry results were biased higher than infrared spectroscopy results during one period but not in the following period. Between the two periods, the procedures and materials used to prepare PAT samples changed in a number of ways, but the switch to quartz dust with a smaller particle size is a likely explanation for the bias difference. Generally, silica analyses have improved in precision over time, and this improvement has taken place for all three of the methods. The colorimetric method has shown the poorest precision of the three methods, but, unlike the differences in bias, the differences in precision have diminished considerably over time. Precision estimates from other studies were compared to those from this study to learn more about sources of variability. The largest source of variability, the differences between laboratories, was large even when laboratories used the same method, as they did in a collaborative study of silica methods.

摘要

相似文献

1
Performance of laboratories measuring silica in the Proficiency Analytical Testing program.
Am Ind Hyg Assoc J. 1992 Jan;53(1):49-56. doi: 10.1080/15298669291359294.
2
Assessment of respirable crystalline silica analysis using Proficiency Analytical Testing results from 2003-2013.利用2003 - 2013年能力验证分析测试结果评估可吸入结晶二氧化硅分析
J Occup Environ Hyg. 2014;11(10):D157-63. doi: 10.1080/15459624.2014.930561.
3
[Analysis of the competences of workplace inspecting laboratories for the determination of free crystalline silica (FCS), based on proficiency testing results].基于能力验证结果对工作场所检测实验室测定游离结晶二氧化硅(FCS)能力的分析
Med Pr. 2006;57(2):115-22.
4
[Free crystalline silica: a comparison of methods for its determination in total dust].[游离结晶二氧化硅:总粉尘中其测定方法的比较]
Med Pr. 2005;56(1):1-8.
5
[Use of roentgen diffractometry and infrared spectroscopy in the analysis of suspended dust samples for fractions of crystalline silicon dioxide].
Z Gesamte Hyg. 1986 Apr;32(4):250-2.
6
Performance of asbestos fiber counting laboratories in the NIOSH proficiency analytical testing (PAT) program.美国国家职业安全与健康研究所能力验证分析测试(PAT)项目中石棉纤维计数实验室的表现。
Am Ind Hyg Assoc J. 1986 May;47(5):259-69. doi: 10.1080/15298668691389748.
7
Methods used by the United States National Institute for Occupational Safety and Health to monitor crystalline silica.
Scand J Work Environ Health. 1995;21 Suppl 2:35-8.
8
[Backgrounds for assessing occupational exposure to crystalline silica dust in Poland and worldwide].[波兰及全球评估职业性接触结晶硅尘的背景]
Med Pr. 2007;58(4):327-44.
9
Laboratory and analytical method performance of lead measurements in paint chips, soils, and dusts.油漆碎片、土壤和灰尘中铅含量测量的实验室及分析方法性能
Am Ind Hyg Assoc J. 1996 Nov;57(11):1035-43. doi: 10.1080/15428119691014378.
10
Monitoring the performance of occupational health laboratories.监测职业健康实验室的绩效。
Am Ind Hyg Assoc J. 1991 Aug;52(8):336-9. doi: 10.1080/15298669191364839.

引用本文的文献

1
Quartz measurement in coal dust with high-flow rate samplers: laboratory study.使用高流量采样器测量煤尘中的石英:实验室研究
Ann Occup Hyg. 2012 May;56(4):413-25. doi: 10.1093/annhyg/mer111. Epub 2011 Dec 19.