McNeill M R, Coulter W A, Hussey D L
Queen's University, Belfast, Northern Ireland.
Int J Prosthodont. 1992 Nov-Dec;5(6):563-7.
This paper demonstrates the potential for cross contamination with bacteria and viruses from impression materials and evaluates the efficacy of four disinfection systems on irreversible hydrocolloid impressions contaminated with Streptococcus sanguis or poliovirus. An irreversible hydrocolloid impression was made of a contaminated acrylic resin template. The impression was disinfected and residual microorganisms were harvested by sonication, cultured, and counted. The results showed that the impression material could act as a vehicle for the transfer of both bacteria and viruses. Further, the virus was shown to be present in the body of the impression and under certain conditions may evade decontamination.
本文展示了印模材料细菌和病毒交叉污染的可能性,并评估了四种消毒系统对被血链球菌或脊髓灰质炎病毒污染的不可逆水胶体印模的消毒效果。用受污染的丙烯酸树脂模板制作不可逆水胶体印模。对印模进行消毒,通过超声处理收集残留微生物,进行培养和计数。结果表明,印模材料可作为细菌和病毒传播的载体。此外,病毒存在于印模内部,在某些情况下可能逃避消毒。