Suppr超能文献

研究绿原酸对藻酸盐印模材料的抗菌效果、物理性能和模型准确性的影响。

Study on the effect of chlorogenic acid on the antimicrobial effect, physical properties and model accuracy of alginate impression materials.

机构信息

Department of Stomatology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China.

Loudi Vocational and Technical College, Loudi, Hunan, China.

出版信息

PeerJ. 2024 Oct 31;12:e18228. doi: 10.7717/peerj.18228. eCollection 2024.

Abstract

BACKGROUND

Dental impressions are essential for accurately capturing the detailed anatomy of teeth and surrounding oral structures. However, these impressions often become contaminated with saliva and blood, making proper disinfection necessary. The application of chemical disinfectants has been associated with negative side effects, leading to suboptimal disinfection practices in clinical settings.

OBJECTIVE

The purpose of this study was to evaluate the effectiveness of chlorogenic acid (CA) as a disinfectant for alginate impression materials, the impact of CA disinfection on the physical properties and dimensional accuracy of alginate impressions was also investigated.

METHODS

The physical properties of alginate impression materials, such as elastic recovery, strain-in-compression, initial setting time, and fluidity, were assessed after mixing the alginate impression materials with three different concentrations of CA solution (10 mg/mL, 15 mg/mL, 20 mg/mL). To evaluate the antimicrobial effect of CA, alginate impressions mixed with a 10 mg/mL CA solution and impressions mixed with distilled water (control group) were contaminated with four types of microorganism: , , , and . Following a five-minute incubation period, a CA solution at a concentration of either 50 mg/mL, 55 mg/mL, or 60 mg/mL was sprayed on the samples for disinfection. Samples were collected at different time intervals (10 min, 20 min, 30 min) and cultured to determine the number of colony-forming units (CFU/mL), providing insight into the antimicrobial efficacy of these CA solutions. The dimensional accuracy of alginate impressions was assessed in three groups: one with alginate impressions mixed with distilled water, another with alginate impressions sterilized with available chlorine (2,000 mg/L) mixed with distilled water, and the last group consisting of alginate impressions mixed with 10 mg/mL CA solution and sprayed with 60 mg/mL CA solution. Both the standard model and the plaster model underwent 3D scanning, and the data were processed and compared by software. The root mean square (RMS) was used as a parameter to evaluate the deviation between models.

RESULTS

All alginate impression materials mixed with either 10 mg/mL, 15 mg/mL, or 20 mg/mL concentrations of CA solution met the ISO 21563 standard for elastic recovery, strain-in-compression, and fluidity. However, only the material mixed with a concentration of 10 mg/mL CA had an initial setting time within the range specified by the T-6505 Japanese industrial standard. The application of CA solution by mixing or spraying showed significant antimicrobial effects on and . There was no significant difference in the dimensional accuracy of the alginate impressions between the group of the CA solution applied, the blank group, or the chlorine intervention group.

摘要

背景

牙印模对于准确捕捉牙齿和周围口腔结构的详细解剖结构至关重要。然而,这些印模经常受到唾液和血液的污染,因此需要进行适当的消毒。化学消毒剂的应用与负面副作用有关,导致临床环境中的消毒效果不理想。

目的

本研究旨在评估绿原酸(CA)作为藻酸盐印模材料消毒剂的有效性,还研究了 CA 消毒对藻酸盐印模材料物理性能和尺寸精度的影响。

方法

混合藻酸盐印模材料后,评估藻酸盐印模材料的物理性能,如弹性恢复、压缩应变、初凝时间和流动性,与三种不同浓度的 CA 溶液(10mg/mL、15mg/mL、20mg/mL)。为了评估 CA 的抗菌效果,将混合有 10mg/mL CA 溶液的藻酸盐印模和混合有蒸馏水的印模(对照组)用四种类型的微生物污染: 、 、 和 。经过五分钟的孵育期后,将浓度为 50mg/mL、55mg/mL 或 60mg/mL 的 CA 溶液喷洒在样品上进行消毒。在不同的时间间隔(10 分钟、20 分钟、30 分钟)收集样本并进行培养,以确定菌落形成单位(CFU/mL)的数量,从而了解这些 CA 溶液的抗菌效果。将藻酸盐印模分为三组进行尺寸精度评估:一组混合有蒸馏水的藻酸盐印模,另一组混合有蒸馏水的用有效氯(2000mg/L)消毒的藻酸盐印模,最后一组混合有 10mg/mL CA 溶液并喷洒 60mg/mL CA 溶液的藻酸盐印模。标准模型和石膏模型均进行了 3D 扫描,通过软件对数据进行处理和比较。均方根(RMS)作为参数用于评估模型之间的偏差。

结果

所有混合有 10mg/mL、15mg/mL 或 20mg/mL CA 溶液的藻酸盐印模材料均符合 ISO 21563 标准的弹性恢复、压缩应变和流动性标准。然而,只有混合有 10mg/mL CA 溶液的材料的初凝时间在 T-6505 日本工业标准规定的范围内。通过混合或喷洒 CA 溶液的应用对 和 表现出显著的抗菌效果。CA 溶液应用组、空白组或氯干预组之间的藻酸盐印模尺寸精度无显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5936/11531742/ca62a0fe39b4/peerj-12-18228-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验