Suppr超能文献

Biologic markers in hospital workers exposed to low levels of ethylene oxide.

作者信息

Schulte P A, Boeniger M, Walker J T, Schober S E, Pereira M A, Gulati D K, Wojciechowski J P, Garza A, Froelich R, Strauss G

机构信息

Industrywide Studies Branch, National Institute for Occupational Safety and Health, Cincinnati, OH 45226.

出版信息

Mutat Res. 1992 Apr;278(4):237-51. doi: 10.1016/s0165-1218(10)80003-5.

Abstract

Operators of hospital sterilizers that use ethylene oxide were studied to determine if there was a relationship between exposure and a battery of biological markers. A total of 73 workers from nine hospitals in the United States (U.S.) and one hospital in Mexico City was evaluated for ethylene oxide exposure during four months prior to collection of peripheral blood. The frequency of hemoglobin adducts (p = 0.0006) and sister-chromatid exchanges (SCEs) (p = 0.002) increased with cumulative exposure to ethylene oxide in U.S. subjects when controlling by regression analysis for various confounding factors, including cigarette smoking. Hemoglobin adducts, but not SCEs, were also increased in Mexican subjects (p = 0.0012). Chromosomal micronuclei showed no consistent relationship with exposure. The U.S. study participants were classified by four-month cumulative exposure levels of 10 ppm-h (n = 8), greater than 0 to 32 ppm-h (n = 32) and greater than 32 ppm-h (n = 11) of ethylene oxide exposure. The group with an exposure of greater than 32 ppm-h had an increased frequency of hemoglobin adducts (p = 0.002) and SCEs (p = 0.0001) compared to the nonexposed group. The estimated mean of the 8-h time-weighted average (8-h TWA) exposure levels for the highest U.S. exposure group (greater than 32 ppm-h) was 0.16 +/- 0.007 ppm (mean +/- SD). A similar exposure-related differential was observed in the Mexican subjects for hemoglobin adducts (p = 0.04) but not for SCEs. The latter finding may have been due to longer shipping times for the specimens in the cytogenetic assays. The estimated mean of the 8-h TWA exposure levels for the highest Mexican exposure group (greater than 32 ppm-h) was 0.48 +/- 0.08 ppm. This study is the third to suggest that exposures less than the U.S. OSHA standard of 1 ppm 8-h TWA result in biochemical and biologic changes. It is not known whether these changes may be indicative of increased risk of disease; however, they do appear to reflect exposure to relatively low levels of ethylene oxide. The exact meaning of these changes is unknown.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验