The Medtronic-Hall valve: a design in 1977 to improve the results of valve replacement.

作者信息

Hall K V

机构信息

Rikshospitalet, Oslo, Norway.

出版信息

Eur J Cardiothorac Surg. 1992;6 Suppl 1:S64-7.

PMID:1389282
Abstract

The prototype Medtronic-Hall valve was developed from improvements to the Lillehei-Kaster and Björk-Shiley valves. The housing was constructed of a single piece of titanium and the disc was composed of pyrolytic carbon; both materials had shown no structural breakdown in previous clinical use. The valve was tested with pulse simulator and electromagnetic flow meter studies and yielded a high effective orifice area. Results in 110 patients were significantly better with the Medtronic-Hall valve than with either of the previous valves. In the 21-mm aortic valve the peak-peak gradient was 12 mmHg; it was 9.2 mmHg in the 23-mm, 3.8 mmHg in the 25-mm, and 2.5 mmHg in the 27-mm. Studies found 5% of forward flow regurgitation in the aortic position and more than desired regurgitation through the mitral valve. After the opening angle of the mitral valve was reduced to 70 degrees, regurgitation reached an acceptable level and the improved hemodynamics resulted in lower transvalvular gradients than in previous mechanical valves. Some patients are naturally more prone to thromboembolism regardless of valve type or anticoagulant therapy; thus the human factor plays a large role in a valve's success. More randomized studies are needed for accurate valve comparison, in addition to investigations of sewing ring factors. Nevertheless, the Medtronic-Hall valve has been used successfully for 15 years and has exhibited no housing fractures.

摘要

相似文献

1
The Medtronic-Hall valve: a design in 1977 to improve the results of valve replacement.
Eur J Cardiothorac Surg. 1992;6 Suppl 1:S64-7.
2
Medtronic-Hall prosthetic aortic valve.美敦力-霍尔人工主动脉瓣
Semin Thorac Cardiovasc Surg. 1996 Jul;8(3):242-8.
3
Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement.二尖瓣置换术中使用Omniscience(STM1)、美敦力-霍尔和比约克-希利凸凹型(70度)人工瓣膜的临床结果比较。
J Thorac Cardiovasc Surg. 1986 Feb;91(2):174-83.
4
A novel pulse duplicator system: evaluation of different valve prostheses.一种新型脉搏复制器系统:不同瓣膜假体的评估。
Thorac Cardiovasc Surg. 2009 Feb;57(1):10-7. doi: 10.1055/s-2008-1038881. Epub 2009 Jan 23.
5
Long-term clinical results after mitral valve replacement with the Björk-Shiley prosthesis.使用比约克-希利人工瓣膜进行二尖瓣置换术后的长期临床结果。
J Thorac Cardiovasc Surg. 1988 Feb;95(2):321-33.
6
Aortic valve replacement with the Hancock standard, Björk-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years.采用汉考克标准型、比约克-希利型和 Lillehei-Kaster 型人工瓣膜进行主动脉瓣置换术。基于 1 至 15 年随访的比较。
J Thorac Cardiovasc Surg. 1989 Jul;98(1):37-47.
7
Primary results with the new Hall-Kaster disc valve prosthesis in mitral position.新型Hall-Kaster盘状瓣人工瓣膜在二尖瓣位置的初步结果。
Thorac Cardiovasc Surg. 1979 Apr;27(2):85-91. doi: 10.1055/s-0028-1096224.
8
Impact of mechanical and biological aortic valve replacement on coronary perfusion: a prospective, randomized study.机械瓣与生物瓣主动脉瓣置换对冠状动脉灌注的影响:一项前瞻性随机研究。
J Heart Valve Dis. 2006 Jan;15(1):5-11; discussion 11.
9
Aortic valve replacement with small-sized disc prostheses (medtronic hall).使用小型盘状人工瓣膜(美敦力霍尔)进行主动脉瓣置换术。
J Heart Valve Dis. 1999 Nov;8(6):680-6.
10
[Doppler echocardiography in assessing mechanical and biological heart valve prostheses].[多普勒超声心动图在评估机械和生物心脏瓣膜假体中的应用]
G Ital Cardiol. 1988 Feb;18(2):121-34.