[Technique of measuring esophageal pressure in rabbits and its application to measurement of pulmonary compliance and resistance].

作者信息

Yang X, Huang G

出版信息

Hua Xi Yi Ke Da Xue Xue Bao. 1992 Mar;23(1):41-4.

PMID:1398622
Abstract

Esophageal pressure (Pes) was measured under non-invasive condition by an esophageal balloon made by ourselves, and the optimal position of rabbits for measuring Pes was explored. The correspondence between Pes and pleural pressure (Ppl) was examined in rabbits during different depths of breathing with varied lengths of balloon and varied depths of insertion of balloon into the esophagus. The results showed that the amplitude of Pes only on supine position was higher than that on the left and right lateral and prone positions, but no significant difference was noticed among the 3 positions. The optimal balloon length was 4-6 cm. The optimal depth of insertion of balloon into the esophagus was 20 cm. The pulmonary dynamic compliance and pulmonary resistance were measured in 11 white rabbits with 5 cm balloon, 20 cm depth of insertion, on the left lateral position. The results were correspondent with other authors. No significant difference was noticed in repeated measurements on 8 of the 11 rabbits 5 days later.

摘要

相似文献

1
[Technique of measuring esophageal pressure in rabbits and its application to measurement of pulmonary compliance and resistance].
Hua Xi Yi Ke Da Xue Xue Bao. 1992 Mar;23(1):41-4.
2
Postural variations in pulmonary resistance, dynamic compliance, and esophageal pressure in neonates.
Crit Care Med. 1983 Jun;11(6):424-7. doi: 10.1097/00003246-198306000-00005.
3
Validation of esophageal balloon technique at different lung volumes and postures.不同肺容量和体位下食管气囊技术的验证
J Appl Physiol (1985). 1987 Jan;62(1):315-21. doi: 10.1152/jappl.1987.62.1.315.
4
Validity of the esophageal balloon technique at high frequencies.高频下食管球囊技术的有效性。
J Appl Physiol (1985). 1993 Mar;74(3):1039-44. doi: 10.1152/jappl.1993.74.3.1039.
5
Measurement of pleural pressure in neonates.新生儿胸膜压力的测量。
J Appl Physiol Respir Environ Exerc Physiol. 1982 Feb;52(2):491-4. doi: 10.1152/jappl.1982.52.2.491.
6
Primate pleuroesophageal tissue barrier frequency response and esophageal pressure waveform bandwidth in health and acute lung injury.健康及急性肺损伤状态下灵长类动物胸膜食管组织屏障频率响应和食管压力波形带宽
Anesthesiology. 2000 Feb;92(2):550-8. doi: 10.1097/00000542-200002000-00039.
7
Comparison of intraesophageal balloon pressure measurements with a nasogastric-esophageal balloon system in volunteers.志愿者中鼻胃-食管气囊系统与食管内气囊压力测量的比较。
Am Rev Respir Dis. 1982 Sep;126(3):583-5. doi: 10.1164/arrd.1982.126.3.583.
8
Esophageal pressure: benefit and limitations.食管压力:益处和局限性。
Minerva Anestesiol. 2012 Aug;78(8):959-66. Epub 2012 Jun 14.
9
A simple method for assessing the validity of the esophageal balloon technique.一种评估食管气囊技术有效性的简单方法。
Am Rev Respir Dis. 1982 Nov;126(5):788-91. doi: 10.1164/arrd.1982.126.5.788.
10
Measurement of pleural pressure at low and high frequencies in normal rabbits.正常家兔低频和高频下胸膜压力的测量。
J Appl Physiol (1985). 1987 Sep;63(3):1142-6. doi: 10.1152/jappl.1987.63.3.1142.