采用高效液相色谱-电化学检测法测定尿中5-羟色醇。

Determination of urinary 5-hydroxytryptophol by high-performance liquid chromatography with electrochemical detection.

作者信息

Helander A, Beck O, Borg S

机构信息

Department of Psychiatry, Karolinska Institute, St. Göran's Hospital, Stockholm, Sweden.

出版信息

J Chromatogr. 1992 Sep 2;579(2):340-5. doi: 10.1016/0378-4347(92)80401-b.

Abstract

A high-performance liquid chromatographic method for the routine determination of elevated urinary levels of the serotonin metabolite 5-hydroxytryptophol (5-HTOL) is described. Urine samples were treated with beta-glucuronidase, and 5-HTOL was isolated by solid-phase extraction on a small Sephadex G-10 column prior to injection onto an isocratically eluted C18 reversed-phase column. Detection of 5-HTOL was performed electrochemically at +0.60 V vs. Ag/AgCl. The limit of detection was ca. 0.05 microM, and the intra-assay coefficients of variation were below 6% with urine samples containing 0.2 and 2.1 microM 5-HTOL and a standard solution of 2.0 microM (n = 5). The recovery of 5-HTOL after the sample clean-up procedure was close to 100%. A good correlation (r2 = 0.97; n = 12) was obtained between the present method and a sensitive and specific gas chromatographic-mass spectrometric method. The total (free plus conjugated) 5-HTOL levels in urine were normally below 0.2 microM, but after an acute dose of alcohol they increased to 0.5-15 microM.

摘要

本文描述了一种高效液相色谱法,用于常规测定尿中血清素代谢物5-羟色醇(5-HTOL)水平升高的情况。尿样用β-葡萄糖醛酸酶处理,在注入等度洗脱的C18反相柱之前,通过在小型葡聚糖G-10柱上进行固相萃取分离5-HTOL。5-HTOL的检测采用电化学法,相对于Ag/AgCl在+0.60 V下进行。检测限约为0.05 microM,对于含有0.2和2.1 microM 5-HTOL的尿样以及2.0 microM的标准溶液(n = 5),批内变异系数低于6%。样品净化程序后5-HTOL的回收率接近100%。本方法与灵敏且特异的气相色谱-质谱法之间具有良好的相关性(r2 = 0.97;n = 12)。尿中总(游离加结合)5-HTOL水平通常低于0.2 microM,但急性摄入酒精后会升高至0.5 - 15 microM。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验