Ikeda M, Yamashina Y, Kamimoto M, Oka Y
Department of Orthopaedic Surgery, Tokai University Oiso Hospital, Kanagawa, Japan.
J Bone Joint Surg Br. 2003 Sep;85(7):1040-4. doi: 10.1302/0301-620x.85b7.13823.
Between 1996 and 2000, we treated ten patients with severely comminuted fractures of the radial head using low-profile mini-plates. Their mean age was 42 years (24 to 71). Three fractures were Mason type III and seven were Mason-Johnston type IV. At a mean follow-up of 28.5 months (15 to 44), all fractures had united. The plates were removed in nine patients. No patient had difficulty with daily activities or symptoms of instability of the elbow. The mean range of flexion of the elbow was from 7 degrees to 135 degrees, with 74 degrees of supination and 85 degrees of pronation. According to the Broberg and Morrey functional elbow index, the mean score was 90.7 points (73 to 100), and the outcome was excellent in three patients, good in six and fair in one. These results compare favourably with those reported previously. The technique is applicable to severely comminuted fractures of the radial head which otherwise would require excision.
1996年至2000年间,我们使用低轮廓微型钢板治疗了10例桡骨头严重粉碎性骨折患者。他们的平均年龄为42岁(24至71岁)。3例骨折为Mason III型,7例为Mason-Johnston IV型。平均随访28.5个月(15至44个月),所有骨折均已愈合。9例患者取出了钢板。没有患者在日常活动中遇到困难或出现肘部不稳定症状。肘部平均屈曲范围为7度至135度,旋后74度,旋前85度。根据Broberg和Morrey肘关节功能指数,平均评分为90.7分(73至100分),3例患者结果为优,6例为良,1例为可。这些结果与先前报道的结果相比具有优势。该技术适用于原本需要切除的桡骨头严重粉碎性骨折。