Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves.

作者信息

Alton M E, Pasierski T J, Orsinelli D A, Eaton G M, Pearson A C

机构信息

Ohio State University Hospitals, Division of Cardiology, Columbus.

出版信息

J Am Coll Cardiol. 1992 Dec;20(7):1503-11. doi: 10.1016/0735-1097(92)90443-q.

Abstract

OBJECTIVES

Our objectives were to characterize by transesophageal echocardiography the normal appearance of the Starr-Edwards prosthetic heart valve and to compare the utility of transesophageal and transthoracic echocardiography in detection of valve abnormality.

BACKGROUND

The Starr-Edwards prosthetic heart valve, the first mechanical valve to be used, has demonstrated excellent durability.

METHODS

Fifty transthoracic and transesophageal echocardiographic studies on 37 patients with 47 Starr-Edwards prosthetic valves were analyzed retrospectively. Six cases of surgically confirmed infective endocarditis were studied.

RESULTS

Vegetation or abscess formation, or both, was identified by transesophageal echocardiography in all six cases of infective endocarditis but was found in only one of these cases by transthoracic echocardiography. Thrombus was detected by transesophageal echocardiography in 9 of 11 patients with transient ischemic attacks or stroke and in 2 patients by transthoracic echocardiography with 3 confirmed at surgery. In 26 of the 30 patients with a mitral Starr-Edwards valve, the valve demonstrated a trivial or mild "closing volume" early systolic or holosystolic leak on transesophageal echocardiography alone. Transthoracic evaluation identified significant mitral regurgitation in six of the eight patients who had this finding on transesophageal echocardiography. Serial studies were performed to assess response to treatment or need for surgical intervention in eight patients. Seventeen valves have been implanted for 12 years; six of these had significant leakage without apparent cause, a finding not observed more recently implanted valves.

CONCLUSIONS

These observations demonstrated the unique utility of transesophageal echocardiography in patients with Starr-Edwards prosthetic valve dysfunction, endocarditis or thrombus formation, and of the clear superiority of transesophageal echocardiography over transthoracic echocardiography in these situations.

摘要

目的

我们的目的是通过经食管超声心动图来描述斯塔尔-爱德华兹人工心脏瓣膜的正常表现,并比较经食管和经胸超声心动图在检测瓣膜异常方面的效用。

背景

斯塔尔-爱德华兹人工心脏瓣膜是首个被使用的机械瓣膜,已证明具有出色的耐用性。

方法

回顾性分析了37例患者的50份经胸和经食管超声心动图研究,这些患者共植入了47个斯塔尔-爱德华兹人工心脏瓣膜。对6例手术确诊的感染性心内膜炎病例进行了研究。

结果

在所有6例感染性心内膜炎病例中,经食管超声心动图均发现了赘生物或脓肿形成,或两者皆有,但经胸超声心动图仅在其中1例中发现。经食管超声心动图在11例短暂性脑缺血发作或中风患者中的9例中检测到血栓,经胸超声心动图在2例患者中检测到血栓,其中3例经手术证实。在30例植入二尖瓣斯塔尔-爱德华兹瓣膜的患者中,有26例仅经食管超声心动图显示瓣膜在收缩早期或全收缩期有轻微或轻度的“关闭容积”反流。经胸评估在经食管超声心动图发现这一情况的8例患者中的6例中发现了明显的二尖瓣反流。对8例患者进行了系列研究,以评估治疗反应或手术干预的必要性。17个瓣膜已植入12年;其中6个出现了无明显原因的严重反流,这一发现最近在新植入的瓣膜中未观察到。

结论

这些观察结果表明,经食管超声心动图在斯塔尔-爱德华兹人工心脏瓣膜功能障碍、心内膜炎或血栓形成患者中具有独特的效用,并且在这些情况下经食管超声心动图明显优于经胸超声心动图。