Temperature profiles and sterilization within a dead-ended tube.

作者信息

Young J H, Ferko B L

机构信息

Pennsylvania State University, Behrend College, Erie.

出版信息

J Parenter Sci Technol. 1992 Jul-Aug;46(4):117-23.

PMID:1453280
Abstract

Use of steam-in-place (SIP) sterilization has increased as the complexity of biotechnology processing equipment has increased. Extensive biological testing is required prior to use of this equipment as no quantitative guidelines exist for the design of SIP sterilizable equipment. Dead-ended geometries present the most difficult challenge to SIP sterilization, but data are not available as to the effects of tube orientation, length and diameter on time required for sterilization. This study examines the effects on sterilization of location within a dead-ended tube and orientation of the tube with respect to the gravitational vector. Temperature profiles and biological kill of Bacillus stearothermophilus were determined for four tube orientations. Kill kinetics were characterized by time to start of kill and cycle log reduction (CLR) times. Both values increased with increasing distance up the tube and orientation of the tube in a more horizontal position. CLR values were as much as ten times greater than those resulting from saturated steam. Projected sterilization times were determined and found to be very dependent on tube orientation. Recommendations are given for sterilization and validation testing of dead-ended geometries.

摘要

相似文献

1
Temperature profiles and sterilization within a dead-ended tube.
J Parenter Sci Technol. 1992 Jul-Aug;46(4):117-23.
2
Sterilization of various diameter dead-ended tubes.各种直径的死端管的灭菌。
Biotechnol Bioeng. 1993 Jun 5;42(1):125-32. doi: 10.1002/bit.260420117.
3
Parameters governing steam sterilization of deadlegs.控制盲管蒸汽灭菌的参数。
J Pharm Sci Technol. 1994 May-Jun;48(3):140-7.
4
Criteria for determining steam sterilization cycles for lubricated and nonlubricated mechanical equipment.确定润滑和非润滑机械设备蒸汽灭菌周期的标准。
Med Instrum. 1979 May-Jun;13(3):168-71.
5
Vaporized hydrogen peroxide sterilization of freeze dryers.冻干机的汽化过氧化氢灭菌
J Parenter Sci Technol. 1992 Nov-Dec;46(6):215-25.
6
Steam sterilization-in-place technology.在位蒸汽灭菌技术。
J Parenter Sci Technol. 1990 Sep-Oct;44(5):253-6.
7
Microbiological efficacy of superheated steam. I. Communication: results with spores of Bacillus subtilis and Bacillus stearothermophilus and with spore earth.过热蒸汽的微生物杀灭效果。I. 通讯:枯草芽孢杆菌和嗜热脂肪芽孢杆菌孢子以及芽孢土样的实验结果
Zentralbl Hyg Umweltmed. 1999 Feb;201(6):541-53.
8
An evaluation of sterilization of endodontic instruments in artificial sponges.人工海绵中牙髓治疗器械灭菌效果的评估。
J Endod. 1998 Jan;24(1):51-3. doi: 10.1016/S0099-2399(98)80215-X.
9
A microwave-powered sterilizable interface for aseptic access to bioreactors that are vulnerable to microbial contamination.一种用于无菌接入易受微生物污染的生物反应器的微波供电可消毒接口。
Biotechnol Prog. 2001 Sep-Oct;17(5):847-51. doi: 10.1021/bp0100732.
10
Effectiveness of three types of sterilization on the contents of sharps containers.三种消毒方式对锐器盒内物品的消毒效果
Quintessence Int. 1995 Nov;26(11):771-8.

引用本文的文献

1
Monitoring Steam Penetration in Channeled Instruments: An Evidence-Based Worst-Case for Practical Situations.监测有通道器械中的蒸汽穿透:基于证据的实际情况最坏案例
Front Med Technol. 2020 Nov 16;2:566143. doi: 10.3389/fmedt.2020.566143. eCollection 2020.