骨水泥型全髋关节置换术中的高交联聚乙烯:61例髋关节的随机研究

Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips.

作者信息

Digas Georgios, Kärrholm Johan, Thanner Jonas, Malchau Henrik, Herberts Peter

机构信息

Department of Orthopaedics, Institute of Surgical Science, Sahlgrenska University Hospital, Göteborg University, Göteborg, Sweden.

出版信息

Clin Orthop Relat Res. 2003 Dec(417):126-38. doi: 10.1097/01.blo.0000096802.78689.45.

Abstract

Highly cross-linked polyethylene (PE) has been introduced as an alternative bearing material in total hip arthroplasty (THA) because of high wear resistance in laboratory tests but the clinical experience of this material is limited. We evaluated a highly cross-linked PE (warm irradiated adiabatic melting, absorbed dose, 95 kGy) in a randomized study of cemented THAs. Cups of the same design but made of conventionally gamma irradiated PE (absorbed dose, 25-40 kGy) constituted the control group. Sixty-one hips (30 women, 30 men) with a median age of 55 years (range, 35-70 years) were included. All patients received a Spectron stem with 28-mm CoCr head. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured with the patient in the supine position from the first postoperative week, whereas examinations done with the patient standing were initiated 3 months after the operation. Dual x-ray absorptiometry and conventional radiography were used to evaluate the bone mineral density and the radiolucencies around the acetabular component. Fifty-two patients (53 hips; 25 highly cross-linked, 28 control) have been followed up for 2 years. At the 2-year followup, the highly cross-linked cups showed 50% reduction of proximal wear compared with the control group, when the patients were studied standing. When evaluated supine, the difference in proximal wear did not reach significance. The migration of the socket, the relative changes of periprosthetic bone mineral density, and the progression of radiolucencies between the immediately postoperative followup and 2-year followup did not differ. Highly cross-linked PE showed increase resistance to wear. Different mechanical properties of the two types of PE studied did not alter the performance of the cup in terms of fixation, periprosthetic bone loss, and radiographic appearance. However, the followup is short and these results are preliminary.

摘要

高交联聚乙烯(PE)因其在实验室测试中具有高耐磨性,已被引入作为全髋关节置换术(THA)中的一种替代承重材料,但这种材料的临床经验有限。我们在一项关于骨水泥型THA的随机研究中评估了一种高交联PE(热辐照绝热熔融,吸收剂量95千戈瑞)。相同设计但由传统γ辐照PE(吸收剂量25 - 40千戈瑞)制成的髋臼杯构成对照组。纳入了61例髋部患者(30名女性,30名男性),中位年龄55岁(范围35 - 70岁)。所有患者均接受了带有28毫米钴铬合金股骨头的Spectron股骨柄。定期对仰卧位或站立位的患者进行放射立体测量检查。术后第一周起在仰卧位测量患者的磨损情况,而站立位检查在术后3个月开始。采用双能X线吸收法和传统X线摄影评估骨密度以及髋臼假体周围的透亮区。52例患者(53髋;25例高交联,28例对照)已随访2年。在2年随访时,当对站立位患者进行研究时,高交联髋臼杯的近端磨损比对照组减少了50%。在仰卧位评估时,近端磨损差异无统计学意义。髋臼假体的移位、假体周围骨密度的相对变化以及术后即刻随访与2年随访之间透亮区的进展情况无差异。高交联PE显示出更高的耐磨性。所研究的两种类型PE的不同机械性能在固定、假体周围骨丢失和影像学表现方面未改变髋臼杯的性能。然而,随访时间较短,这些结果是初步的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验