Riddell Michaela A, Byrnes Graham B, Leydon Jennie A, Kelly Heath A
Victorian Infectious Diseases Reference Laboratory (VIDRL)/WHO Western Pacific Measles Regional Reference Laboratory, 10 Wreckyn Street, North Melbourne, 3051 Victoria, Australia.
Bull World Health Organ. 2003;81(10):701-7. Epub 2003 Nov 25.
To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay.
Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20.
DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing.
These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus.
确定在商业酶免疫测定中,干燥静脉血(DVB)样本是否是检测麻疹特异性IgG的血清的可接受替代物。
从澳大利亚维多利亚州的98例疑似麻疹病例和1153名学童中采集血清和DVB配对样本。所有样本均使用达德拜林酶免疫诊断抗麻疹病毒/IgG免疫测定法进行检测。DVB样本使用试剂盒提供的样本缓冲液或磷酸盐缓冲盐水-吐温20中的5%干奶粉进行洗脱。
与在磷酸盐缓冲盐水-吐温20中的5%干奶粉中洗脱的DVB样本相比,用样本缓冲液洗脱的DVB样本与血清样本的线性相关性明显更好。为提高血清和DVB样本的可比性,对DVB的光密度(OD)值应用了1.28的调整因子。这种调整还能根据试剂盒方案规定的α计算,直接从OD值定量测定mIU/ml的麻疹IgG滴度。对于在4℃下储存少于6个月的DVB样本,与血清检测结果相比,该测定法的总体灵敏度为98.4%,特异性为97.2%。
这些结果表明,DVB样本有可能与达德拜林酶免疫测定系统一起广泛用于确定个体和人群对麻疹病毒的免疫力。