Suppr超能文献

固定剂扩散速率的重新评估。

Reassessment of the rate of fixative diffusion.

作者信息

Start R D, Layton C M, Cross S S, Smith J H

机构信息

Department of Histopathology, Northern General Hospital, Sheffield.

出版信息

J Clin Pathol. 1992 Dec;45(12):1120-1. doi: 10.1136/jcp.45.12.1120.

Abstract

The diffusion of fixatives is slow. Early work using plasma gels and animal tissues showed the distance penetrated by a fixative to be a simple function of the fixation time but this relation has not been established in human tissues. The rates of diffusion into whole human spleens were measured for three primary fixatives over periods ranging from one to 25 days. A positive correlation was demonstrated between penetration distance (mm) and fixation time (hours). The diffusion rates were slower than those in previous studies. These results have possible implications for the handling of surgical specimens.

摘要

固定剂的扩散速度很慢。早期使用血浆凝胶和动物组织的研究表明,固定剂渗透的距离是固定时间的一个简单函数,但这种关系在人体组织中尚未得到证实。在1至25天的时间段内,测量了三种主要固定剂渗入整个人体脾脏的速率。结果表明,渗透距离(毫米)与固定时间(小时)之间呈正相关。扩散速率比先前研究中的要慢。这些结果可能对外科手术标本的处理有影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2392/495013/e1872341f876/jclinpath00426-0080-a.jpg