• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[The reuse of 29-gauge spinal needles following combined spinal-epidural anesthesia].

作者信息

Möllmann M, Lübbesmeyer H, Holst D, Vandermeersch E, van Aken H

机构信息

Klinik und Poliklinik für Anästhesiologie und operative Intensivmedizin, Westfälische Wilhelms-Universität Münster.

出版信息

Anaesthesist. 1992 Dec;41(12):769-71.

PMID:1489076
Abstract

The technique of combined spinal epidural anaesthesia (CSE) combines the versatility of spinal with the variability of epidural anaesthesia. Spinal application of the local anaesthetic achieves a fast response, reliable sensorial and motor block at a low dose with little toxicity. The epidural catheter allows for the duration of surgical anaesthesia to be extended and provides analgesia for the postoperative period. As the incidence of post dural puncture headache (PDPH) is inversely related to the size of the spinal needle, PDPH rarely or never occurs when 29 gauge needles are used. In 1775 parturients receiving spinal anaesthesia for caesarean section, Dittmann et al. [4] reported an incidence of PDPH of 1.37% with 29 gauge needles. The 29 gauge needle produced by Becton-Dickinson is the one now most frequently used for this technique. It is recommended that these needles be reused after resterilization. The objective of this study was to examine how clean 29 gauge spinal needles really are after resterilization. MATERIALS AND METHODS. Fifteen needles (29 gauge; Becton-Dickinson) were routinely used for combined spinal epidural anaesthesia. After identification of the epidural space at the L3-4 spinal segment with the 18 gauge Tuohy needle, the 29 gauge needle was advanced through the Tuohy needle. Immediately after use the needles were cleaned, rinsed with 20 ml distilled water, dried with pressurized air and subsequently resterilized in gas. Preparation of the used needles was in accordance with the manufacturer's recommendations ("wash, rinse, dry, sterilize before initial and each subsequent use") and with generally accepted principles [6]. Two needles were additionally cleaned in an ultrasonic bath for 15 min. The needles were examined using a scanning electron microscope. After this analyses, eight needles were sterilized again and then taken for hygienic examination. They were incubated with trypticase soy broth and checked for bacterial growth. RESULTS. Scanning electron microscopy (ScEM) showed organic impurities on all needles. These impurities were equally distributed among all needles. Even the two cleaned in the ultrasonic bath were not free of organic particles. However, no material defects or damage could be seen. Hygienic evaluation proved sterility as no bacterial growth could be detected. CONCLUSION. Owing to the possibility of medico-legal consequences, which sometimes occur a long time after anaesthesia has been given, we think it is unwise to reuse such needles. We hope that disposable and cheap 29 gauge needles will soon become available.

摘要

相似文献

1
[The reuse of 29-gauge spinal needles following combined spinal-epidural anesthesia].
Anaesthesist. 1992 Dec;41(12):769-71.
2
Ten years of experience with accidental dural puncture and post-dural puncture headache in a tertiary obstetric anaesthesia department.一家三级产科麻醉科室十年间意外硬膜穿破及硬膜穿破后头痛的经验
Int J Obstet Anesth. 2008 Oct;17(4):329-35. doi: 10.1016/j.ijoa.2007.04.009. Epub 2008 Aug 8.
3
[Development of incidence of post-dural puncture headache in patients undergoing caesarean section in spinal anaesthesia at the Department of Obstetrics and Gynecology in Olomouc during 2003-2004].[2003 - 2004年奥洛穆茨妇产科剖宫产脊髓麻醉患者硬膜外穿刺后头痛发生率的研究]
Cas Lek Cesk. 2006;145(3):204-8.
4
A comparison of 25 gauge Quincke spinal needle with 26 gauge Eldor spinal needle for the elective Caesarian sections: insertion characteristics and complications.25号昆克腰穿针与26号埃尔多腰穿针用于择期剖宫产的比较:穿刺特性及并发症
Kathmandu Univ Med J (KUMJ). 2003 Oct-Dec;1(4):263-6.
5
Evaluation of combined spinal-epidural anesthesia using two different techniques.使用两种不同技术对腰麻-硬膜外联合麻醉进行评估。
Reg Anesth. 1994 May-Jun;19(3):169-74.
6
Complications with 25-gauge and 27-gauge Whitacre needles during combined spinal-epidural analgesia in labor.
Int J Obstet Anesth. 2001 Jul;10(3):168-71. doi: 10.1054/ijoa.2000.0834.
7
Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25 g Quincke, 27 g Quincke and 27 g Whitacre spinal needles.剖宫产脊髓麻醉后硬膜穿刺头痛:25G Quincke针、27G Quincke针和27G Whitacre脊髓针的比较
J Ayub Med Coll Abbottabad. 2008 Jul-Sep;20(3):10-3.
8
[CSE--the combination of spinal and epidural anesthesia].[CSE——脊髓麻醉与硬膜外麻醉联合使用]
Reg Anaesth. 1991 Dec;14(6):108-12.
9
No risk of metal toxicity in combined spinal-epidural anesthesia.腰麻-硬膜外联合麻醉不存在金属中毒风险。
Anesth Analg. 1999 Feb;88(2):393-7.
10
[The effect of injection speed and needle gauge on the spread of sensory blockade in spinal anesthesia].[注射速度和针规格对脊髓麻醉中感觉阻滞范围的影响]
Reg Anaesth. 1990 Sep;13(7):148-52.